医学
颈动脉内膜切除术
分流(医疗)
外科
麻醉
算法
临床终点
术中神经生理监测
B组
颈动脉
随机对照试验
计算机科学
作者
I. Zogogiannis,Christos Iatrou,Miltiadis K Lazarides,Theodossia D Vogiatzaki,Mitchell S. Wachtel,Petros K. Chatzigakis,V. Dimitriou
出处
期刊:PubMed
日期:2011-10-01
卷期号:21 (3): 367-73
被引量:30
摘要
We evaluated whether the use of an intraoperative algorithm based on cerebral oximetry with near-infrared refracted spectroscopy (NIRS) monitoring, could aid in the intraoperative decision for shunt placement, in patients undergoing carotid endarterectomy (CEA).In this prospective, randomized, controlled study were included 253 patients who underwent CEA under general anesthesia. They were randomly allocated in Group A (n=83) using NIRS monitoring and the suggested algorithm, Group B (n=84) using NIRS monitoring without the algorithm and Group C (n=86) who served as controls. Shunt placement criterion for Group A and B was 20% drop in ipsilateral regional saturation from the baseline value recorded before surgery. Primary endpoint of the study was to evaluate the use of the intraoperative algorithm based on NIRS monitoring, in the intraoperative decision for shunt placement, in patients undergoing carotid endarterectomy. Additionally, we examined whether this might affect the rate of postoperative neurologic deficits.When compared with Group A, Group B and Group C had 3.7 times (99% c.i. 1.5-9.5) and 70.6 times (99% c.i. 15-724.3) respectively, greater likelihood of having a shunt placed. When compared with Group B, Group C had 19.4 times (99% c.i. 4.3-191.2) greater likelihood of having a shunt placed. Regarding the rate of postoperative neurologic deficits no significant difference was found between the three groups.The use of a specific algorithm based on NIRS monitoring, in patients undergoing CEA, may aid in the intraoperative decision for shunt placement.
科研通智能强力驱动
Strongly Powered by AbleSci AI