Al-based alloys named M1, M2, M3, M4, and M5 doped with different atomic percentage (at%) of cobalt and manganese as cast and submitted at two heat treatments (600°C and 1100°C) were analyzed by using electrochemical techniques to evaluate their corrosion resistance immersed in 3 M KOH. With the heat treatments applied to the alloys, the sample M2 (65% Al, 20% Co, and 15% Mn) observed the highest corrosion resistance with values of , , and as cast, 600°C, and 1100°C, respectively. The latter was in agreement with the calculated from the polarization curves where the values decrease based on the heat treatment applied as follows: for 1100, 600, and as cast, respectively. Co concentration above 20% increases the corrosion current ( ) and decreases the polarization resistance of the remain samples. The chemical analysis done with EDS and X-ray diffraction made confirmed the presence of compounds such as CoAl, Co2Al5, Co2Al9, MnAl4, and MnAl6.