纤维接头
胃
极限抗拉强度
体外
解剖
医学
化学
材料科学
内科学
复合材料
生物化学
作者
Mario Kreszinger,Bojan Toholj,Aleksandar Ačanski,Sebastijan Baloš,Marko Cincović,Marko Pećin,Marija Lipar,Ozren Smolec
标识
DOI:10.24099/vet.arhiv.170130
摘要
The primary objective of this study was to determine whether polyglyconate or polydioxanone resorptive surgical materials are superior in terms of tensile strength retention in implantation in the cadaveric submucosa of the stomach wall.A secondary objective was to compare the tensile strength retention, in the same conditions, of polydioxanone suture materials produced by different manufacturers.Five samples of resorptive suture materials (polyglyconate (Maxon ® , Covidien), polydioxanone (PDS ® , Ethicon, PDX ® Kruuse, Surgicryl ® SMI), Catgut chromic, Kruuse) all diameter USP 2-0, were incubated in vitro in the cadaveric submucosa of the stomach wall for fifty days.Measurements of tensile strength were made on day 0 and the 10 th day.Polyglyconate (Maxon ® ) showed the greatest initial tensile strength.After 10 days of incubation in the submucosa of the stomach, the tensile strength decreases more rapidly for polyglyconate (Maxon ® ) in comparison to polydioxanone sutures, but they were still higher compared with the others on the 10 th day.Polydioxanone Surgicryl ® had the highest tensile strength retention -91.4% after 10 days of incubation in the submucosa of the stomach.Polydioxanone PDX ® maintained only 58.5% of its initial tensile strength.Polydioxanone Surgicryl ® had the highest initial Young's modulus.