One of the current challenges in the context of structural health monitoring
(SHM) of important infrastructures, such as large span bridges,
is how to manage the large amount of data produced by the SHM
systems and make it readily available to the bridge management authorities
in the form of performance indicators. In this study, the possibilities of early detection of structural damage through the analysis of
the measured structural response of a cable-stayed bridge to daily and
seasonal temperature variations are evaluated. A continuous monitoring
system has been installed in the Corgo Bridge, here selected as
case-study, which is acquiring data without significant interruptions
for more than half year. The monitoring systems is described, and the
software being used to access remotely and in real-time the measured
data is presented.
The ability of detecting damage using the structural response to
thermal loads is evaluated applying Multilinear Regression Analysis
(MLR) and Principal Component Analysis (PCA) for removing the environmental
effects of the structural response. At this stage, simulated
datasets were adopted so that at least one year of data can be used in
order to remove the environmental effects from the structural response
of the bridge in the undamaged state. The simulations were carefully
performed by generating realistic thermal fields in the crosssections
of the bridge using a finite element thermal analysis in which
the boundary conditions are defined using the measured wind velocity,
radiation, ambient temperature and air temperature inside the
box-girder. The comparisons with the measurements of the existing
temperature sensors (of which more than one year of data is available)
reveal that a good agreement could be achieved. The thermal action
is then applied to a mechanical finite element model of the bridge to
obtain the simulated structural behaviour. Again, the comparison with
the available measured data reveals a reasonable agreement, indicating
that the simulated datasets are representative of the real structural
behaviour.
Several damage scenarios are simulated, mainly involving stiffness
losses of the stay-cables and it is shown that the adopted methodology,
jointly with the installed monitoring system, is able to provide
early detection of small damages.