医学
胰岛素泵
1型糖尿病
糖尿病酮症酸中毒
糖尿病
低血糖
血糖性
逻辑回归
队列
2型糖尿病
内科学
胰岛素
儿科
内分泌学
作者
Roque Cardona‐Hernandez,Anke Schwandt,Hessa Alkandari,Heiko Bratke,Agata P Chobot,Nicole Coles,Sarah Dawn Corathers,Damla Gökşen,Peter W Goss,Zineb Imane,Katrin Nagl,Stephen O’Riordan,Craig Jefferies
出处
期刊:Diabetes Care
[American Diabetes Association]
日期:2021-03-02
卷期号:44 (5): 1176-1184
被引量:136
摘要
OBJECTIVE Insulin delivery methods, glucose-monitoring modalities, and related outcomes were examined in a large, international, diverse cohort of children and adolescents with type 1 diabetes from the Better Control in Pediatric and Adolescent Diabetes: Working to Create Centers of Reference (SWEET) -Registry. RESEARCH DESIGN AND METHODS Participants with type 1 diabetes of ≥1 year, aged ≤18 years, and who had documented pump or sensor usage during the period August 2017–July 2019 were stratified into four categories: injections–no sensor (referent); injections + sensor; pump–no sensor; and pump + sensor. HbA1c and proportion of patients with diabetic ketoacidosis (DKA) or severe hypoglycemia (SH) were analyzed; linear and logistic regression models adjusted for demographics, region, and gross domestic product per capita were applied. RESULTS Data of 25,654 participants were analyzed. The proportions of participants (adjusted HbA1c data) by study group were as follows: injections–no sensor group, 37.44% (8.72; 95% CI 8.68–8.75); injections + sensor group, 14.98% (8.30; 95% CI 8.25–8.35); pump–no sensor group, 17.22% (8.07; 95% CI 8.03–8.12); and pump + sensor group, 30.35% (7.81; 95% CI 7.77–7.84). HbA1c was lower in all categories of participants who used a pump and/or sensor compared with the injections–no sensor treatment method (P < 0.001). The proportion of DKA episodes was lower in participants in the pump + sensor (1.98%; 95% CI 1.64–2.48; P < 0.001) and the pump–no sensor (2.02%; 95% CI 1.64–2.48; P < 0.05) groups when compared with those in the injections–no sensor group (2.91%; 95% CI 2.59–3.31). The proportion of participants experiencing SH was lower in pump–no sensor group (1.10%; 95% CI 0.85–1.43; P < 0.001) but higher in the injections + sensor group (4.25%; 95% CI 3.65–4.95; P < 0.001) compared with the injections–no sensor group (2.35%; 95% CI 2.04–2.71). CONCLUSIONS Lower HbA1c and fewer DKA episodes were observed in participants using either a pump or continuous glucose monitoring (CGM) or both. Pump use was associated with a lower rate of SH. Across SWEET centers, use of pumps and CGM is increasing. The concomitant use of pump and CGM was associated with an additive benefit.
科研通智能强力驱动
Strongly Powered by AbleSci AI