Development of rapid analysis methods for radium-226 in environmental water samples.

镭 质谱法 γ射线光谱法 环境放射性 降水 环境科学 样品(材料) 样品制备 放射化学 放射性核素 化学 色谱法 物理 核物理学 气象学
作者
van A.J.H. Es,Elsje May
出处
期刊:University of Surrey - Surrey Open Research repository
标识
DOI:10.15126/thesis.00850269
摘要

Rapid, routine chemical analysis methods are available for most radionuclides. However, for Ra-226 methods are available, but these are far less routine and are therefore generally cost and time intensive. This is particularly true for the analysis of Ra-226 in environmental waters, as the activity concentrations of this sample type is comparatively low. To address this, accurate and traceable analytical methods for measuring Ra-226 in environmental water samples (1 L), in < 24 h, have been developed and optimised. Initial investigations were focused on gamma and alpha spectrometry with a view of them being implemented in a mobile facility. On site analysis, using a mobile facility, has the potential to increase the time and cost efficiency of analysis through negating the need for sample dispatch and transport. Investigations showed that non-destructive gamma spectrometry, on a portable ORTEC HPGe detector provided a minimum detectable activity (MDA) of 3.6 ± 0.5 Bq/L. These measurements were subject to U-235 interferences, corrections for which are discussed within the text. Investigation were also carried out into using co-precipitation with barium sulphate prior to measurement by gamma spectrometry. Co precipitation removed the U-235 interference by providing separation of Ra-226 from U-235 prior to measurement. Co-precipitation of Ra as Ba(Ra)SO4 gave chemical recoveries > 90% and increased the counting efficiency, through improving the sample-detector geometry. This combination allowed for an MDA of 31 ± 4.5 mBq to be achieved. Alpha spectrometry was also investigated as a portable technique. The developed method pre-concentrated samples using manganese dioxide resin and separated Ra from the sample matrix using barium sulphate micro co-precipitation. The optimised method provided MDAs < 5 mBq for a 12 h count time with calculated chemical recoveries > 75%. The procedural time for non destructive gamma spectrometry was less than that for alpha spectrometry, 1.5 h and 8 h respectively. Gamma spectrometry with co precipitation required operator times of < 30 min as compared to 4 h for alpha spectrometry. However, the higher background count rate and lower counting efficiencies for gamma spectrometry, meant that the count times required were longer and the MDAs achievable much higher than alpha spectrometry. The count times for radiometric techniques is what limits sample throughput. Multiple detectors for alpha spectrometry is an economically viable option, with each counting chamber requiring very little space. The potential of multiple detectors for gamma spectrometry is primarily limited by cost. However, if more detectors were purchased there is the added complication of interferences between simultaneous measurements in a confined space. Direct measurement by inductively coupled mass spectrometry (ICP-MS), using an Agilent 8800 ICP-QQQ-MS (Agilent Technologies, UK), was considered. Although it is not field deployable, it provided a means of eliminating the count times associated with radiometric techniques which proved to be the limiting factor in sample throughput. The instrument’s collision reaction cell was optimised to allow for online separation of interferences reducing the background to 0 at a mass to charge ratio of 226 (m/z 226) resulting in a limit of detection of 0.01 Bq L 1 based on the signal to noise ratio. Handling of complex matrices was achieved through use of the instrument’s high matrix introduction system. Direct analysis of Ra-226 in samples of 10 and 100 Bq/L provided measurement uncertainties of < 30 and < 10% respectively. Direct measurement of samples by ICP-MS removes the count times associated with radiometric techniques, with measurement times of < 5 min per samples, allowing for a much higher sample throughput for higher activity samples. Combining ICP-MS with a suitable pre-concentration technique was also investigated. To do this, the extraction chromatography and ion-exchange resins (TK100 and AG® 50W X8) were both characterised for Ra-226, with a focus of loading high volume (1 L) samples. The Kd values for Ra on TK100 resin were 2-3 orders of magnitude lower than on AG®50W at acid concentrations of 0.01-0.1 M, with peak values of 7 × 102 and 6 × 104, respectively. However, TK100 was more selective than AG® 50W-X8, showing no affinity at pH 2 for Ca, a major element in most environmental waters. TK100 was used to pre-concentrate samples prior to ICP-MS measurement. This allowed for a pre-concentration factor of 100, with minimal signal suppression suggesting larger pre-concentration factors are feasible. A pre-concentration factor of 200 would allow for the measurement of Ra-226 at concentrations in the order of 0.5 Bq L 1 with measurement uncertainties < 10%. These findings proved that ICP-MS could be a viable alternative to alpha spectrometry as a means of assessing drinking water quality, with respect to its Ra-226 content, providing a similar sample throughput with the added benefit of being a cost effective way to measure multiple stable elements and other long-lived radionuclides.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
踏实的又夏完成签到 ,获得积分10
1秒前
1秒前
zws发布了新的文献求助10
1秒前
汤圆发布了新的文献求助30
1秒前
panfan完成签到,获得积分10
1秒前
2秒前
sheng完成签到,获得积分10
2秒前
朴素的新晴完成签到,获得积分20
2秒前
韩韩完成签到 ,获得积分10
2秒前
2秒前
3秒前
顶刊相见发布了新的文献求助10
3秒前
小杨完成签到,获得积分10
3秒前
少川完成签到 ,获得积分10
4秒前
乐乐的应助被kk采纳,获得10
4秒前
4秒前
perper完成签到,获得积分10
5秒前
5秒前
天天向上的应助被既白采纳,获得10
5秒前
5秒前
5秒前
然嘻嘻发布了新的文献求助10
5秒前
6秒前
异构金属材料给异构金属材料的求助进行了留言
6秒前
CipherSage的应助被潇洒的辣条采纳,获得10
6秒前
7秒前
cxr发布了新的文献求助10
7秒前
xia完成签到,获得积分10
7秒前
刘婉敏发布了新的文献求助10
7秒前
7秒前
NexusExplorer的应助被害羞的慕晴采纳,获得50
7秒前
高兴白昼完成签到 ,获得积分10
7秒前
xiaoming完成签到,获得积分10
9秒前
和谐花生发布了新的文献求助10
9秒前
高远亮发布了新的文献求助10
9秒前
perper发布了新的文献求助10
9秒前
Downey发布了新的文献求助10
9秒前
策略发布了新的文献求助10
9秒前
10秒前
11秒前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
拉伸高分子熔体中缠结行为的模拟和小角中子散射研究 1700
Grapes 1000
The World Atlas of Wine 9th edition 1000
奈特基础组织学:配套组织病理学(第4版)(Netter's Essential Histology With Correlated Histopathology) 800
John McDowells Bildungstheorie 800
八旗制度の研究 600
热门求助领域 (近24小时)
化学 材料科学 医学 生物 纳米技术 计算机科学 工程类 有机化学 化学工程 生物化学 物理 复合材料 内科学 催化作用 光电子学 人工智能 细胞生物学 无机化学 物理化学 数学
热门帖子
关注 科研通微信公众号,转发送积分 8178280
求助须知:如何正确求助?哪些是违规求助? 9569046
关于积分的说明 21802436
捐赠科研通 7773138
什么是DOI,文献DOI怎么找? 3432735
关于科研通互助平台的介绍 2556770
邀请新用户注册赠送积分活动 2478274