摘要
This study aims to report our experience of using fluid-ventilated, gas-permeable scleral contact lenses (SCLs) for visual rehabilitation of patients with keratoconus and irregular astigmatism after refractive surgery. This is a noncomparative interventional case series reporting eight consecutive patients fitted with SCLs because of irregular astigmatism following the failure of other optical corrections. Retrospective chart review and data analysis included age, sex, etiology prior to lens fitting, visual outcomes, follow-up time, and complications. Twelve eyes of eight patients were studied. All eyes were fitted with SCLs due to unsatisfactory vision with spectacle correction or other contact lens modalities. Five eyes had keratoconus and seven had irregular corneas post refractive surgery. The mean follow-up period was 14.4 ± 1.3 months (range 11–17 months). The mean age was 32.63 ± 7.68 years (range 18–48 years). The average steepest keratometry(Kmax) of our series was 49.56 ± 12.2 D. The mean refractive astigmatism was 5.50 ± 5.3 D. The mean best corrected visual acuity (BCVA) in logarithm of the minimum angle of resolution improved from 0.71 ± 0.50 (range 0.10–1.40) to 0.05 ± 0.07 (range 0.00–0.15) after SCL fitting (p < 0.001). All reported eyes achieved significant improvement in the BCVA with SCL fitting. None of the patients discontinued to wear SCLs. SCLs should be considered lenses of choice in irregular corneas refractory to conventional optical correction.