摘要
One of the biggest issues in electrocoagulation (EC) water treatment processes is electrode fouling, which can cause decreased coagulant production, increased ohmic resistance and energy consumption, and reduced contaminant removal efficiency, among other operational problems. While it has been suggested that switching the current direction intermittently (i.e., polarity reversal, PR) can help mitigate electrode fouling, conflicting results about the utility of this approach have been reported in the literature. The objective of this study was to systematically investigate the effects of PR frequency and current density on the performance of Fe-EC and Al-EC. It was found that operating Fe-EC under the PR mode reduced neither electrode fouling nor energy consumption. Notably, the Faradaic efficiency (ϕ) in Fe-EC decreased with increasing PR frequency; ϕ was as low as 10% when a PR frequency of 0.5 minutes was employed. Unlike Fe-EC, operating Al-EC under the PR mode resulted in high coagulant production efficiencies, reduced energy consumption, and diminished electrode fouling. In addition to comparing PR-EC and DC-EC, a novel strategy to minimize electrode fouling was investigated. This strategy involved operating Fe DC-EC and Al DC-EC with a Ti-IrO2 cathode, whose fouling by Ca- and Mg-containing minerals could be readily avoided by periodically switching the current direction.