再现性
组内相关
医学
核医学
放射科
心包
心外膜脂肪
变异系数
一致相关系数
心外膜脂肪组织
斯皮尔曼秩相关系数
脂肪组织
狭窄
计算机断层摄影术
相关系数
磁共振成像
协议限制
断层摄影术
成像生物标志物
作者
Judith Gronwald,Svante S. Gersch,Zoé M. Böttiger,Clara Hagedorn,Torben Lange,Sören Jan Backhaus,Sebastian Kelle,Constanze Schmidt,Karl Toischer,Andreas Schuster,Alexander Schulz
摘要
BACKGROUND: Epicardial adipose tissue volume (EATV) is increasingly recognized as a cardiometabolic risk marker associated with adverse outcomes. The most established approach for EATV quantification is cardiac computed tomography (CT). MRI offers a radiation-free alternative allowing simultaneous assessment of myocardial function and tissue characteristics; however, standardization and validation are limited. PURPOSE: To evaluate a standardized MRI-based method for EATV quantification and determine its agreement with CT. STUDY TYPE: Retrospective. POPULATION: 127 patients with aortic stenosis (AS) (78 ± 6 years; 38% female) who underwent paired CT and MRI and 11 volunteers (74 ± 7 years, 45% female) who underwent repeat MRI after ≥ 6 weeks. FIELD STRENGTH/SEQUENCE: Short-axis balanced steady-state free precession cine sequence at 3T (AS patients) and 1.5T (volunteers). ASSESSMENT: On CT, EATV was quantified by manual delineation of the visceral pericardium and voxel-thresholding (-190 to -30 HU). MRI-based EATV quantification used manual volumetry with delineation of the visceral pericardium and epicardium on end-diastolic short-axis cine stacks. STATISTICAL TESTS: Inter-modality agreement was assessed by Spearman correlation and Bland-Altman analysis. Reproducibility was evaluated in 20 patients using intraclass correlation coefficient (ICC) and coefficient of variation (CoV). Scan-rescan reproducibility for MRI-derived EATV quantification was assessed using ICC and linear regression. p < 0.05 was considered significant. RESULTS: ), with a significant moderate correlation (ρ = 0.627) between measures. Inter- and intra-observer analyses showed excellent reproducibility for both modalities (CT: intra-observer ICC: 0.983, inter-observer ICC: 0.994; MRI: intra-observer ICC: 0.955, inter-observer ICC: 0.970). MRI-derived EATV quantification also showed excellent scan-rescan reproducibility (ICC: 0.985). DATA CONCLUSION: The standardized MRI-based approach enabled highly reproducible EATV measurements with excellent repeatability. Agreement with CT was moderate, with systematically higher values on MRI, limiting direct comparability. EVIDENCE LEVEL: 3. STAGE OF TECHNICAL EFFICACY: 2.
科研通智能强力驱动
Strongly Powered by AbleSci AI