The crank rocker mechanism and its’ evolution mechanism have been applying widely in the manufacture and the floor level of the minimum transmission angle(*min≥[+]) should be confirmed in the design. According to the relationship between the length of the linking rods of the crank rocker mechanism and its’ evolution mechanism, the accurate location of ,min has been induced by the geometric method in the paper.