Supraglottic airway (SGA) is an alternative to endotracheal intubation, however endotracheal intubation is often essential. One method to convert from an SGA to an endotracheal tube (ETT) is utilizing the SGA as a conduit for fiberoptic-guided advancement of an Aintree catheter (airway exchange catheter), and exchange of the SGA for an ETT. In this prospective randomized study, we compared two SGA devices in facilitating this exchange. Subjects were randomized to receive either the i-gel® or LMA® Supreme™ SGA. The SGA was placed and an Aintree intubation catheter was inserted through the SGA over a fiberoptic bronchoscope. Next, the SGA was removed, leaving the Aintree within the trachea, and an ETT was placed over the Aintree catheter and advanced into the trachea. The i-gel group exhibited shorter time to successful intubation (median, 191 vs. 434 seconds; P = .002). The i-gel group also had fewer study subjects requiring more than one attempt for successful Aintree placement (33% vs. 75%, P = .02). The i-gel group showed superior laryngeal view score (LVS) (6 vs. 4; P = .003). The i-gel SGA achieved a faster time to successful intubation, higher rate of first attempt Aintree placement, and superior LVS.