医学
图像质量
原设备制造商
核医学
放射科
图像噪声
甲状腺
对比度(视觉)
辐射暴露
内科学
图像(数学)
计算机科学
操作系统
人工智能
作者
Qianling Li,Zicheng Zhao,Chen Yang,Fandong Zhu,Chenweng Sun,Zhenhua Zhao
摘要
Abstract We investigate the efficacy of organ-effective modulation (OEM) technique for thyroid dose reduction among various body habitus and its impact on image quality in chest non-contrast computed tomography (CT). We prospectively enrolled 64 patients who underwent non-contrast chest CT from January to May 2022. The skin-absorbed radiation dose over the thyroid (Dthyroid) was obtained using a thermoluminescence dosemeter. Signal-to-noise ratio and image noise was also quantitatively assessed. In subjective analyses, two radiologists independently evaluated images based on a 5-point scale. The OEM group showed a markedly decrease in Dthyroid when compared with the non-OEM group (p < 0.05). No significant difference was observed regarding the image noise (p < 0.05), except for the ventral air space. The subjective scores of two radiologists showed no significant differences between the non-OEM and OEM groups. OEM can effectively reduce the radiation exposure of thyroid without compromising on image quality in non-contrast chest CT.