医学
速尿
下腔静脉
急性失代偿性心力衰竭
四分位间距
心力衰竭
血管内容积状态
前瞻性队列研究
超声波
利尿剂
超声科
心脏病学
内科学
外科
麻醉
放射科
血流动力学
作者
Stefan Tchernodrinski,Brian Lucas,Ambarish M. Athavale,Carolina Candotti,Bosko Margeta,Ariel Katz,Rudolf Kumapley
摘要
Purpose Measurement of the inferior vena cava (IVC) diameters may improve decision-making for patients hospitalized with acute decompensated heart failure. Nevertheless, little is known about how the IVC is affected by loop diuretics. We sought to determine if bolus infusions of intravenous furosemide affect IVC diameters measured by hand-carried ultrasonography. Methods We conducted a prospective cohort study at a public teaching hospital from September 2009 through June 2010. Physician investigators performed IVC ultrasonography on a convenience sample of 70 hospitalized adults who were prescribed intravenous furosemide for the diagnosis of acute decompensated heart failure. Results Participants' median baseline IVC diameter was 2.38 cm (interquartile range, 1.91–2.55 cm). At 1–2 hours after furosemide, IVC diameters decreased an average of 0.21 cm (95% CI, 0.13–0.29 cm) and remained significantly below baseline at 2–3 hours after furosemide by an average of 0.15 cm (95% CI, 0.07–0.22 cm). Conclusions IVC diameters of adults diagnosed with acute decompensated heart failure become measurably smaller after single doses of intravenous furosemide. Whether this represents a true change in volume status has not been studied. © 2014 Wiley Periodicals, Inc. J Clin Ultrasound 43:187–193, 2015