医学
交联聚乙烯
全髋关节置换术
射线照相术
聚乙烯
外科
关节置换术
髋关节置换术
全髋关节置换术
牙科
复合材料
材料科学
作者
Michele Francesco Surace,Luca Monestier,Ettore Vulcano,Steven F. Harwin,Paolo Cherubino
出处
期刊:Orthopedics
[Slack Incorporated (United States)]
日期:2015-09-01
卷期号:38 (9): 556-561
被引量:8
标识
DOI:10.3928/01477447-20150902-05
摘要
The clinical and radiographic outcomes of 88 patients who underwent primary total hip arthroplasty with either conventional polyethylene or cross-linked polyethylene (XLPE) from the same manufacturer were compared. There were no significant differences between the 2 subpopulations regarding average age, gender, side affected, or prosthetic stem and cup size. The average follow-up was 104 months (range, 55 to 131 months). To the authors’ knowledge, this is the longest follow-up for this particular insert. Clinical and radiographic evaluations were performed at 1, 3, 6, and 12 months and then annually. Results showed that XLPE has a significantly greater wear reduction than that of standard polyethylene in primary total hip arthroplasty. At the longest available follow-up for these specific inserts, XLPE proved to be effective in reducing wear. [ Orthopedics. 2015; 38(9):556–561.]