铌
材料科学
钛
钛合金
腐蚀
冶金
弹性模量
合金
模数
钨
钽
复合材料
作者
Bruno Leandro Pereira,C.M. Lepienski,Viviane Seba,Guibert Hobold,Paulo Soares,Bor Shin Chee,Pedro Akira Bazaglia Kuroda,Erico Saito Szameitat,Leonardo Luis Santos,Carlos Roberto Grandini,Michael Nugent
标识
DOI:10.1590/1980-5373-mr-2020-0405
摘要
The present study produced binary titanium-niobium alloys Ti-xNb with high niobium percentage (x = 50, 80 e 90 wt.%) aiming to apply it as a base material in osseous implant devices. The produced TiNb alloys presented a cubic crystalline phase, lower corrosion rate than titanium, lower elastic modulus values, and superior cellular viability than titanium and niobium. The Ti50Nb alloy among all analyzed metallic substrates showed the best values of elastic modulus, corrosion properties, wettability, and cellular viability. Thus, this work suggests a Ti/Nb ratio close to 1 (Ti50Nb) displays optimum characteristics to apply in orthopedic devices.
科研通智能强力驱动
Strongly Powered by AbleSci AI