医学
危险系数
心脏病学
内科学
植入式心律转复除颤器
置信区间
心脏再同步化治疗
临床终点
相对风险
心力衰竭
心源性猝死
比例危险模型
射血分数
临床试验
作者
Yu-Qiu Li,Shuang Zhao,Keping Chen,Yang-Gang Su,Wei Hua,Silin Chen,Zhaoguang Liang,Wei Xu,Yan Dai,Xiaohan Fan,Shu Zhang
出处
期刊:PubMed Central
[National Institutes of Health]
日期:2019-03-01
卷期号:16 (3): 259-264
被引量:4
标识
DOI:10.11909/j.issn.1671-5411.2019.03.001
摘要
OBJECTIVE: To evaluate the PR to RR interval ratio (PR/RR, heart rate-adjusted PR) as a prognostic marker for long-term ventricular arrhythmias and cardiac death in patients with implantable cardioverter defibrillator (ICDs) and cardiac resynchronization therapy with defibrillators (CRT-D). METHODS: We retrospectively analyzed data from 428 patients who had an ICD/CRT-D equipped with home monitoring. Baseline PR and RR interval data prior to ICD/CRT-D implantation were collected from standard 12-lead electrocardiograph, and the PR/RR was calculated. The primary endpoint was appropriate ICD/CRT-D treatment of ventricular arrhythmias (VAs), and the secondary endpoint was cardiac death. RESULTS: = 0.024. CONCLUSIONS: A PR/RR ≥ 18.5% at baseline can serve as a predictor of future VAs and cardiac death in ICD/CRT-D recipients.