摘要
Sir: It is with great interest that I read the article by Baumann et al. in the May issue of the Journal that emphasizes the overriding importance of the number of perforators (three to five) that should be incorporated in deep inferior epigastric perforator (DIEP) flap dissections to minimize the incidence of fat necrosis.1 I respectfully disagree with this conclusion, as our group routinely bases our DIEP flaps on only one or two perforators (and occasionally three), with a very low incidence of fat necrosis. The strategy for successful DIEP flap reconstruction should not be focused on perforator number, but should instead revolve around the concept of taking an anatomical inventory of the available perforators before proceeding with flap design and dissection. In 2007, I published in this Journal an algorithm for microsurgical breast reconstruction based on perforator anatomy.2 This simple algorithm takes into account three equally important structural features that should be assessed during DIEP flap elevation—perforator size, number, and location. Using this algorithm, our group would expect, for example, an excellent clinical result for a DIEP flap based on two perforators, each ranging in size from 1.5 to 3 mm, and for a DIEP flap based on a single 3-mm perforator if centrally located. Since our 2007 report to the Journal, our group has performed 76 more DIEP flaps adhering to the microsurgical algorithm with good results—two failures (2.6 percent) and four instances of fat necrosis (5.2 percent). Our largest number of flaps continue to be based on two perforators (1.5 to 3.0 mm; 74 percent) followed by one perforator (>3.0 mm, centrally located; 18 percent) followed by three perforators (1.5 to 3.0 mm; 8 percent). In this most recent series, we have not had to convert intraoperatively to an MS-2 or to use more than three perforators. There are three reasons why two different institutions, each reporting large series of DIEP flaps, could come up with different recommendations for flap dissection. First, we do not use perforators that measure less than 1.5 mm in diameter. The perforators are measured at the site of anterior rectus fascial penetration after releasing the fascial collar and allowing them to plump up. In the series of Baumann et al., there is no specification as to where or how perforator diameter is measured. Furthermore, small perforators were measured as less than 0.5 mm in diameter, medium perforators between 0.5 and 1.0 mm in diameter, and large perforators greater than 1.0 mm diameter. Using these criteria, none of the small and medium perforators and an unknown percentage of the large perforators would have been considered usable at our institution. Knowing that flow through a vessel is proportional to the fourth power of the radius, a 1- to 2-mm increase in perforator diameter translates into a huge increase in potential blood flow. That having been said, we advocate a more thorough search and an anatomical inventory of the available perforators to select the largest and best. Furthermore, it is curious that The Methodist Hospital group would use perforators of these diminutive sizes when, in a previous study from that institution, the minimal recommended perforator diameter was 1.5 mm—a lower limit with which we completely agree.3 Second, we continue to require that the perforators have a palpable pulse after dissection. Although this is a qualitative factor, we cannot overstate its importance as an indicator of perforator strength and flow. There are numerous situations in our clinical practice where Doppler flow through a perforator may be present; however, if after topical 4% lidocaine dilatation and limited adventitiectomy a palpable pulse is not present, strong consideration should be given to the incorporation of a different perforator or going to the opposite side. Third, perforator distribution within the flap is a predictor of success. In our 2007 series, we noted that a single, large (>3.0 mm) centrally located perforator was, in fact, a very desirable clinical scenario. Two smaller perforators (each 1.5 to 3.0 mm) also represent a desirable clinical scenario. Because these perforators arise from either the medial or lateral row, spacing and location of the perforators is usually satisfactory. Occasionally, two closely clustered periumbilical perforators should be supplemented by a third farther away, usually located more proximal on the medial or lateral row. The DIEP flap remains our first choice for autogenous breast reconstruction in appropriate candidates, as this technique properly applied consistently delivers high-quality results with minimal morbidity. The article by Baumann et al. represents an unnecessary slide back to the muscle-sparing transverse rectus abdominis musculocutaneous technique, which at our institution serves as a backup or lifeboat procedure when perforator anatomy is unfavorable. John T. Lindsey, M.D. East Jefferson General Hospital 4228 Houma Boulevard, Suite 500 Metairie, La. 70006