摘要
Percutaneous transhepatic stent-graft placement usually requires more than a 12 F sheath, which has a higher potential risk of peritoneal hemorrhage. A case of postoperative portal vein hemorrhage after pancreaticoduodenectomy treated using a Viabahn VBX balloon expanding stent-graft is described in this report. The stent-graft was delivered using an 8 F sheath through a transhepatic approach and deployed from the superior mesenteric vein to the main portal vein. Hemostasis was achieved and graft patency was confirmed one year after the procedure.