伊瓦卡夫托
医学
囊性纤维化
肺
通风(建筑)
肺功能测试
内科学
核医学
囊性纤维化跨膜传导调节器
机械工程
工程类
作者
Julius F. Heidenreich,Philipp Josef Kuhl,Jan‐Peter Grunz,Robin Hendel,Corona Metz,Andreas Max Weng,Thomas Benkert,Helge Hebestreit,Thorsten Alexander Bley,Herbert Köstler,Simon Veldhoen
出处
期刊:Radiology
[Radiological Society of North America]
日期:2023-07-01
卷期号:308 (1)
被引量:11
标识
DOI:10.1148/radiol.230084
摘要
Background The triple combination of the cystic fibrosis transmembrane regulator (CFTR) modulators elexacaftor, tezacaftor, and ivacaftor (hereafter, elexacaftor/tezacaftor/ivacaftor) has a positive effect on lung function in patients with cystic fibrosis (CF). Purpose To compare three-dimensional (3D) ultrashort echo time (UTE) MRI functional lung data to common functional lung parameters in assessing lung function in patients with CF undergoing elexacaftor/tezacaftor/ivacaftor therapy. Materials and Methods In this prospective feasibility study, 16 participants with CF consented to undergo pulmonary MRI with a breath-hold 3D UTE sequence at baseline (April 2018–June 2019) and follow-up (April–July 2021). Eight participants received elexacaftor/tezacaftor/ivacaftor after baseline, and eight participants with unchanged treatment served as the control group. Lung function was assessed with body plethysmography and lung clearance index (LCI). Image-based functional lung parameters, such as ventilation inhomogeneity and ventilation defect percentage (VDP), were calculated from signal intensity change between MRI scans at inspiration and expiration. Metrics at baseline and follow-up were compared within groups (permutation test), correlation was tested (Spearman rank correlation), and 95% CIs were calculated (bootstrapping technique). Results MRI ventilation inhomogeneity correlated with LCI at baseline (r = 0.92, P < .001) and follow-up (r = 0.81, P = .002). Mean MRI ventilation inhomogeneity (baseline, 0.74 ± 0.15 [SD]; follow-up, 0.64 ± 0.11; P = .02) and mean VDP (baseline, 14.1% ± 7.4; follow-up, 8.5% ± 3.3; P = .02) decreased from baseline to follow-up in the treatment group. Lung function was stable over time (mean LCI: 9.3 turnovers ± 4.1 at baseline vs 11.5 turnovers ± 7.4 at follow-up; P = .34) in the control group. In all participants, correlation of forced expiratory volume in 1 second with MRI ventilation inhomogeneity was good at baseline (r = −0.61, P = .01) but poor during follow-up (r = −0.06, P = .82). Conclusion Noncontrast 3D UTE lung MRI functional parameters of ventilation inhomogeneity and VDP can be used to assess lung function over time in patients with CF and can add regional information to established global parameters, such as LCI. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Iwasawa in this issue.
科研通智能强力驱动
Strongly Powered by AbleSci AI