医学
期限(时间)
捆绑
心脏病学
内科学
单中心
中心(范畴论)
心脏起搏
结晶学
量子力学
物理
复合材料
化学
材料科学
作者
Todd L. Teigeler,Jeffrey Kolominsky,Chau Vo,Richard K. Shepard,Gautham Kalahasty,Jordana Kron,José F. Huizar,Károly Kaszala,Alex Y. Tan,Jayanthi N. Koneru,Kenneth A. Ellenbogen,Santosh K. Padala
出处
期刊:Heart Rhythm
[Elsevier BV]
日期:2021-01-09
卷期号:18 (5): 743-749
被引量:119
标识
DOI:10.1016/j.hrthm.2020.12.031
摘要
The short-term safety, feasibility, and performance of His-bundle pacing (HBP) leads have been reported; however, their longer-term performance beyond 1 year remains unclear.The purpose of this study was to examine the intermediate-term performance and safety of HBP.All HBP lead implants at Virginia Commonwealth University between January 2014 and January 2019 were analyzed. HBP was performed using a Medtronic SelectSecure 3830-69 cm pacing lead.Of 295 attempts, successful HBP implantation (selective or nonselective) was seen in 274 cases (93%). Mean follow-up duration was 22.8 ± 19.5 months (median 19.5; interquartile range 11-33). Mean age was 69 ± 15 years; 58% were males; and ejection fraction <50% was noted in 30%. Indications for pacemaker included sick sinus syndrome in 41%, atrioventricular block in 36%, cardiac resynchronization therapy in 7%, and refractory atrial fibrillation in 15%. Selective HBP was achieved in 33%. Mean HBP capture threshold at implant was 1.1 ± 0.9 V at 0.8 ± 0.2 ms, which significantly increased at chronic follow-up to 1.7 ± 1.1 V at 0.8 ± 0.3 ms (P <.001). Threshold was ≥2.5 V in 24% of patients, and 28% had an increase in HBP threshold ≥1 V. Loss of His-bundle capture at follow-up (septal right ventricular pacing) was seen in 17%. There was a total of 31 (11%) lead revisions, primarily for unacceptably high thresholds.Although HBP can prevent or improve pacing-induced cardiomyopathy, the elevated capture thresholds, loss of His-bundle capture, and lead revision rates at intermediate follow-up are of concern. Longer-term follow-up data from multiple centers are needed.
科研通智能强力驱动
Strongly Powered by AbleSci AI