Laboratory Model for Evaluation of Incipient Transformer Thermal Fault Involving Insulating
作者
Helena Maria Wilhelm,Paulo O. Fernandes,Thatiane Tamyris Kuczera Pereira,Geovana Carolina dos Santos,Daniel da Conceição Aroucha Filho,Arley Mar,Marcelo Ribeiro
出处
期刊:日期:2019-06-01卷期号:: 120-123被引量:1
标识
DOI:10.1109/eic43217.2019.9046540
摘要
In order to age thermally upgraded kraft paper immersed in insulating oil without aging the oil, an “aging device” was built in which a copper electric resistance was covered with insulating paper and the setup was immersed in insulating oil contained in a vessel. The oil was water cooled to keep its temperature below 60° C, while paper's temperature was raised up to 500 °C. The experiment allowed the determination of the CO2/CO rate variation against aging time and temperature. The generation of other decomposition products, namely furan compounds, methanol and ethanol was also determined against aging time and temperature. Paper aging status was also determined through degree of polymerization (DP). The aging of oil was also monitored.