材料科学
生物传感器
检出限
纳米材料
表面改性
生物分子
作者
Yuna Jung,Sangrim Kang,Jong Min An,Junyang Jung,Dokyoung Kim
标识
DOI:10.1016/j.dyepig.2020.108700
摘要
Abstract Anthrax is an infection caused by bacterium Bacillus anthracis (B. anthracis), and is an old disease that poses a new threat to humans as a biological weapon. Gram-staining and polymerase chain reaction (PCR)-based assays of specimens are standard diagnostic tools for anthrax, but it is time-consuming and limited for the on-site application. In this study, we disclose a porous silicon-based nanoprobe for the detection of dipicolinic acid (DPA), which is a crucial biomarker of the anthrax spore, and its practical sensing applications. The surface of the porous silicon nanoparticles (pSiNPs) was functionalized with multiple amine arms, via a ring-opening click amination and was grafted with terbium ion (Tb3+). A double antenna effect from DPA and pSiNPs to Tb3+ was appeared dramatically and was accompanied by a significant fluorescence enhancement that had high selectivity, sensitivity, and fast response time. The resulting pSiNPs-Tb formulation was used to detect DPA in real water samples and the stimulated Bacillus subtilis (B. subtilis) spores. Besides, the DPA sensing application on the cellulose-based paper was successfully demonstrated as a real-time on-site sensing kit. We believe the demonstrations in this study could encourage further applications throughout a wide variety of fields.
科研通智能强力驱动