Development of Zinc Oxide-based UV Photodetector Devices as a Wearable UV Index Monitor
作者
Crescentiana Cathlea Jessiena,Astria Nur Irfansyah,Tasripan,Erry Dwi Kurniawan,Shobih,Diki Purnawati
出处
期刊:日期:2025-11-12卷期号:: 220-225
标识
DOI:10.1109/icramet67419.2025.11349945
摘要
Excessive exposure to ultraviolet (UV) rays can cause premature aging and skin cancer, thus requiring an effective UV monitoring system. This study developed a zinc oxide (ZnO)-based UV photodetector on a flexible polyimide (PI) substrate using the spin coating method with an interdigitated electrode (IDE) pattern forming a metal-semiconductor-metal (MSM) structure. The current-voltage (IV) characterization results show a symmetrical nonlinear curve with a threshold voltage $\pm 0.1 \mathrm{~V}$, dark current $0.142 \mu \mathrm{~A}$, and photocurrent $5.08 \mu \mathrm{~A}$, which decreases dramatically to 33.58 nA when bent. The time response characteristics show a rise time of 0.83 ms and a fall time of 0.34 ms. The UV-Vis absorption spectrum is in the range of $290-405 \mathrm{~nm}$, which indicates the UV-A region and part of the visible light, with a bandgap energy value of 3.275 eV. The photodetector was then integrated into a wearable UV index monitor system using a transimpedance amplifier circuit and a microcontroller for real-time signal processing. Testing showed UV index reading accuracy with 96.9% conformity rate to WHO reference data. However, performance declined over time due to material degradation and electrode damage, requiring design improvements for long term use.