摘要
HomeCirculationVol. 122, No. 2Clinician’s Guide to Cardiopulmonary Exercise Testing in Adults Free AccessReview ArticlePDF/EPUBAboutView PDFView EPUBSections ToolsAdd to favoritesDownload citationsTrack citationsPermissions ShareShare onFacebookTwitterLinked InMendeleyReddit Jump toFree AccessReview ArticlePDF/EPUBClinician’s Guide to Cardiopulmonary Exercise Testing in AdultsA Scientific Statement From the American Heart Association Gary J. Balady, MD, FAHA, Chair, Ross Arena, PhD, FAHA, Kathy Sietsema, MD, Jonathan Myers, PhD, FAHA, Lola Coke, RN, PhD, Gerald F. Fletcher, MD, FAHA, Daniel Forman, MD, Barry Franklin, PhD, FAHA, Marco Guazzi, MD, PhD, Martha Gulati, MD, Steven J. Keteyian, PhD, Carl J. Lavie, MD, Richard Macko, MD, Donna Mancini, MD, Richard V. Milani, MD, FAHA, , Council on Epidemiology and Prevention Council on Peripheral Vascular Disease Interdisciplinary Council on Quality of Care and Outcomes Research Gary J. BaladyGary J. Balady Search for more papers by this author , Ross ArenaRoss Arena Search for more papers by this author , Kathy SietsemaKathy Sietsema Search for more papers by this author , Jonathan MyersJonathan Myers Search for more papers by this author , Lola CokeLola Coke Search for more papers by this author , Gerald F. FletcherGerald F. Fletcher Search for more papers by this author , Daniel FormanDaniel Forman Search for more papers by this author , Barry FranklinBarry Franklin Search for more papers by this author , Marco GuazziMarco Guazzi Search for more papers by this author , Martha GulatiMartha Gulati Search for more papers by this author , Steven J. KeteyianSteven J. Keteyian Search for more papers by this author , Carl J. LavieCarl J. Lavie Search for more papers by this author , Richard MackoRichard Macko Search for more papers by this author , Donna ManciniDonna Mancini Search for more papers by this author , Richard V. MilaniRichard V. Milani Search for more papers by this author , Search for more papers by this author , Council on Epidemiology and Prevention Search for more papers by this author , Council on Peripheral Vascular Disease Search for more papers by this author and on behalf of Interdisciplinary Council on Quality of Care and Outcomes Research Search for more papers by this author and on behalf of the American Heart Association Exercise, Cardiac Rehabilitation, and Prevention Committee of the Council on Clinical Cardiology Originally published28 Jun 2010https://doi.org/10.1161/CIR.0b013e3181e52e69Circulation. 2010;122:191–225Other version(s) of this articleYou are viewing the most recent version of this article. Previous versions: June 28, 2010: Previous Version 1 Exercise testing remains a remarkably durable and versatile tool that provides valuable diagnostic and prognostic information regarding patients with cardiovascular and pulmonary disease. Exercise testing has been available for more than a half century and, like many other cardiovascular procedures, has evolved in its technology and scope. When combined with exercise testing, adjunctive imaging modalities offer greater diagnostic accuracy, additional information regarding cardiac structure and function, and additional prognostic information. Similarly, the addition of ventilatory gas exchange measurements during exercise testing provides a wide array of unique and clinically useful incremental information that heretofore has been poorly understood and underutilized by the practicing clinician. The reasons for this are many and include the requirement for additional equipment (cardiopulmonary exercise testing [CPX] systems), personnel who are proficient in the administration and interpretation of these tests, limited or absence of training of cardiovascular specialists and limited training by pulmonary specialists in this technique, and the lack of understanding of the value of CPX by practicing clinicians.Modern CPX systems allow for the analysis of gas exchange at rest, during exercise, and during recovery and yield breath-by-breath measures of oxygen uptake (V̇o2), carbon dioxide output (V̇co2), and ventilation (V̇e). These advanced computerized systems provide both simple and complex analyses of these data that are easy to retrieve and store, which makes CPX available for widespread use. These data can be readily integrated with standard variables measured during exercise testing, including heart rate, blood pressure, work rate, electrocardiography findings, and symptoms, to provide a comprehensive assessment of exercise tolerance and exercise responses. CPX can even be performed with adjunctive imaging modalities for additional diagnostic assessment. Hence, CPX offers the clinician the ability to obtain a wealth of information beyond standard exercise electrocardiography testing that when appropriately applied and interpreted can assist in the management of complex cardiovascular and pulmonary disease.Although CPX has long been used in the assessment of athletic performance and in research venues, its burgeoning value in the clinical setting has prompted the American Heart Association to convene a writing group of experts in the field to generate this “Clinician’s Guide to Cardiopulmonary Exercise Testing in Adults.” The purpose of this document is to supplement existing exercise testing guidelines with a comprehensive overview of CPX. Accordingly, this “Clinician’s Guide” provides a summary and interpretation of the most relevant literature to address the following broad topic areas: (1) CPX technology; (2) key CPX variables and their clinical implications; (3) current clinical and emerging applications of CPX; and (4) interpretation and reporting of CPX test data. The recommendations made in the present document are based primarily on expert consensus interpretation of published data when available, because there are essentially no randomized trials to address diagnostic and prognostic applications of CPX. This “Clinician’s Guide” has been peer-reviewed by outside reviewers nominated by the American Heart Association and has been approved by the Science and Advisory Coordinating Committee of the American Heart Association. This “Clinician’s Guide” will be considered current unless the American Heart Association revises or withdraws it from distribution.The abbreviations for selected terms used throughout this document appear in Table 1. Table 1. AbbreviationsCO2Carbon dioxideCPXCardiopulmonary exercise testingC(a−v)o2Arteriovenous oxygen differenceEOBExercise oscillatory breathingFeco2Fraction of carbon dioxide in expired airFeo2Fraction of oxygen in expired airFEV1Forced expiratory volume in 1 secondMETMetabolic equivalentMVVMaximum voluntary ventilationO2OxygenOUESOxygen-uptake efficiency slopePetco2Partial pressure of end-tidal carbon dioxidePeto2Partial pressure of end-tidal oxygenRERRespiratory exchange ratioV̇co2Carbon dioxide outputVdVolume of dead spaceV̇eMinute ventilationV̇E/V̇co2Ventilatory equivalent of carbon dioxideV̇E/V̇o2Ventilatory equivalent of oxygenV̇o2Oxygen uptakeVTVentilatory thresholdGas Exchange Physiology in Health and DiseaseThe ability to perform physical exercise is critically related to the cardiovascular system’s capacity to supply oxygen (O2) to the muscles and the pulmonary system’s ability to clear carbon dioxide (CO2) from the blood via the lungs. The cardiovascular and respiratory systems work together to provide both a delivery system (of O2) and a removal system (of CO2) from the tissues. There are 4 processes that occur to make this happen: Pulmonary ventilation, or the movement of air into and out of the lungs;Pulmonary diffusion, or the exchange of O2 and CO2 between the lungs and the blood;Transport of O2 and CO2 in the blood;Capillary gas exchange, or the exchange of O2 and CO2 between the capillary blood and the working muscle.The first 2 processes are referred to as external respiration because they involve the movement of gases from the ambient air into the lungs and then the blood. The fourth step is commonly termed internal respiration because it involves gas exchange between the blood and the tissues. These 2 processes are linked by the circulatory system. CPX is valuable because taxing the mechanisms responsible for external and internal respiration by exercise can frequently reveal abnormalities not apparent at rest. In addition, typical pulmonary and cardiac function tests performed at rest cannot reliably determine exercise capacity or the particular mechanisms underlying exercise intolerance among individual subjects with cardiac or pulmonary disease.The increase in oxygen uptake by the working muscles is facilitated most importantly by an increase in cardiac output (heart rate×stroke volume), which may increase to up to 6 times that at rest. Cardiac output is also redistributed away from nonactive tissues (eg, splanchnic and renal) to the skeletal muscles, which facilitates greater O2 delivery. A concomitant increase in blood flow to the lungs occurs, both by the increase in cardiac output and by vasodilation of the pulmonary vessels. A greater extraction of O2 from the blood also occurs as the blood perfuses the muscles, which results in a widening of the arteriovenous oxygen (a−V̇o2) difference.In normal subjects, minute ventilation (V̇e) increases in proportion to the increase in work rate. During inhalation, only part of the tidal volume of air reaches the alveoli, where gas exchange takes place in the lungs. The air that remains in the respiratory passages that does not participate in gas exchange is known as the dead space volume (Vd). During exercise, dilation of the respiratory passages causes the Vd to increase, but because tidal volume also increases, adequate alveolar ventilation, and therefore gas exchange, is maintained. This is termed normalventilation-perfusionmatching. Many disease states can alter the matching of ventilation to perfusion. For example, in many manifestations of pulmonary disease, exercise is limited by a higher than normal dead space, because there are fewer healthy tissues in the lungs with which gas exchange can take place. The increase in V̇e during exercise must be matched by an increase in blood flow; that is, cardiac output must increase to appropriately match ventilation so that necessary gas exchange can occur. One of the hallmarks of chronic heart failure is an impaired cardiac output response to exercise; this can also lead to a mismatching of ventilation to perfusion, in which ventilation must increase disproportionately to the metabolic needs to compensate for inadequate perfusion. The degree to which ventilation is abnormally heightened during exercise is directly related to the severity of disease and is a strong marker of prognosis. The various expressions of this response and other causes of inefficient ventilation and their relation to prognosis are detailed in later sections of the present document.1Procedures for CPXCalibration of Gas Exchange SystemsModern CPX systems contain rapidly responding O2 and CO2 sensors that allow for the calculation of oxygen uptake and carbon dioxide output at rest, during exercise, and during recovery, as frequently as breath by breath. Although manufacturers’ recommendations vary considerably regarding calibration, all CPX systems should be calibrated immediately before each exercise test. This should include calibration of airflow, volumes, and both the O2 and CO2 analyzers. Gas analyzers and flow meters are prone to drift, which can lead to serious errors. Today, nearly all commercially available systems have convenient calibration procedures controlled by a microprocessor. Validation studies have been performed on many of the computerized systems.2–4 Because ambient conditions affect the concentration of O2 in the inspired air, temperature, barometric pressure, and humidity should be taken into account. Many modern CPX systems automatically quantify these conditions and make appropriate adjustments to calculate the inspired O2 concentration. If this feature is not available, these atmospheric conditions should be measured by an external device and input into the CPX system. This should be done before every calibration of the system. A copy of the calibration report should be printed before each test and should be attached to the test report. Valid interpretation of test results is possible only if calibration values are appropriate. The test should not be performed if the system does not calibrate.The following specific calibration procedures should be performed to ensure that valid data are obtained: Room air (Fio2) should read 20.93±0.03% O2 at 0% humidity; however, the precise fraction is dependent on humidity and should be adjusted accordingly. A calibration source that contains 100% nitrogen should read 0% O2. The analyzer should be checked further by simulating the fraction of expired O2 (Feo2) during the test, that is, approximately 16% O2. Calibration gases should be used as provided by the system manufacturer. The exercise laboratory should be well ventilated to ensure a representative fraction of inspired O2; a small fan is helpful for this purpose.The CO2 analyzer should read a room air fraction of 0.03±0.02% and should not change when the 100% N2 or 16% O2 fractions are sampled from the calibration tanks. The CO2 analyzer should be checked further by simulating the fraction of expired CO2 (Feco2) during exercise, that is, approximately 4% CO2.For breath-by-breath CPX systems in particular, it is also necessary to check the inherent response times of the analyzer and to precisely determine the transport delay between sampling point and analyzers. It is important that the system meet the specifications outlined by the manufacturer; this feature is available in most systems.Measurement of ventilatory volume can now be easily achieved with 1 of several devices, including pneumotachometers, mass flow sensors, pitot tube flow meters, and turbine volume transducers. All can be validated before testing by ascertaining a stable baseline (0 L/min) and injecting a known volume (usually 3 or 4 L) from a syringe. It is preferable to perform several injections at different flow rates to ensure stability; the average error should be within ±3% of the known volume.5Software ConsiderationsThe many different CPX systems each have unique software for processing, analyzing, and displaying data. The software determines the type and amount of data extracted, the summary reports, data sampling and averaging, and graphical reports. Most systems permit the user to define the specific responses and the way in which they are displayed during the test and are summarized in test reports. These are important considerations because they can have a significant effect on the test results. Reporting of test results will be discussed in detail below (see Assessing and Reporting CPX Data). Patient characteristics used in the calculation of normal predicted values, including age, sex, and body size, are also generally entered into the CPX software. Equations for normal standards can vary widely, and population specificity should thus be considered when a patient’s response is evaluated as a percentage of normal.Modern CPX systems provide a wide variety of automated reports, data averaging and sampling techniques, calibration methods, and graphics. Although computerization has facilitated ease of use, it has also led to some confusion regarding which variables to consider and how the data should be expressed and interpreted. One important area in need of standardization is data sampling. Differences in sampling (eg, breath by breath, an averaged number of breaths, or time intervals such as 10, 15, or 30 seconds) can have a profound effect on test results. There is a need for consistency in this area that appropriately balances high precision but high variability (breath-by-breath method) with imprecision but low variability (long sampling intervals); therefore, for routine clinical use, if feasible, the averaging of data over 20- to 30-second intervals is generally sufficient to reduce the effect of random noise in breath-by-breath measurements. It is recommended that rolling 30-second averages be used that are printed frequently (eg, 10 seconds).6 It is useful to display the key data in a time down format with rest, beginning of exercise, and peak exercise clearly defined. There are also an unlimited number of graphical choices, and on most systems, these can be specified by the user. As a minimum, a graphical display of the V-slope7 and the V̇e/V̇o2 and V̇e/V̇co2 responses with time should be printed to verify the ventilatory threshold (VT). Examples of these are presented in Figure 1 and will be discussed in detail below (see Variables From CPX and Their Physiological Implications). Download figureDownload PowerPointFigure 1. V-slope, ventilatory equivalents, and end-tidal methods for the detection of VT. See text for details.Automated interpretation programs that provide diagnoses based on the CPX test results are common. These can be useful supplements to the test report but should not be relied on for making clinical decisions; any automated interpretation, including determination of VT, should be overread by an individual experienced in the applications of CPX.System Maintenance and Quality ControlIt is important that validation of the CPX system be performed on a regular basis. Gas exchange measurements are highly reproducible within a given subject if testing methods are consistent. One method often used to validate a system’s performance is to test laboratory staff members at a matched submaximal work rate on a periodic basis (perhaps every 4 to 6 months). It is recommended that several staff members participate in this process, each using a slightly different steady state submaximal work rate. As long as a subject is in a steady state (ie, a constant metabolic rate), V̇o2 and other CPX variables should be reproducible. Four to 6 minutes of constant-load, low- to moderate-intensity exercise is required for most individuals to achieve a steady state. Acceptable limits of variation for V̇o2, V̇co2, and V̇e for a given steady state work rate are shown in Table 2.8,9 In addition to being reproducible, V̇o2 should fall within an acceptable range when compared with estimated V̇o2 based on the external work rate. The recommended values for steady state work are best estimated with American College of Sports Medicine equations.10 In this context, estimated V̇o2 is only valid during steady state exercise; the inaccuracies of estimating V̇o2 during progressive exercise are well documented.10,11Table 2. Limits of Variation in Gas-Exchange Variables Obtained by Repeated Study of the Same Subject at a Given Submaximal Work RateVariableVariation, %Data from Jones8 and Wilmore et al.9Oxygen uptake±5.0Carbon dioxide output±6.0Minute ventilation±5.5RER±3.0Even when appropriate calibration procedures are followed, modern automated CPX systems can provide results that appear to be accurate yet may be erroneous. Respiratory gas exchange simulators that calibrate CPX systems are available.12 These systems involve injecting a precise gas mixture at various specified ventilation rates that can simulate rest and exercise at known ventilation, V̇o2, and V̇co2 rates. Although not necessary, simulators provide reference values for comparison with a CPX system and therefore can be helpful to ensure precision of a system. However, these systems do not perfectly simulate exercise conditions in humans, including variations in breathing patterns, temperature and humidity corrections, and other factors.Selection of Exercise Test ProtocolAssessment of exercise capacity typically is performed on a motorized treadmill or a stationary cycle ergometer. In the United States, however, treadmill exercise is generally the preferred modality. Furthermore, untrained subjects will usually terminate cycle exercise because of quadriceps fatigue at a V̇o2 that is on average 10% to 20% below their treadmill peak V̇o2.13 Cycle ergometry also requires subject cooperation in maintaining pedal speed at the desired level, usually ≈60 rpm, although modern ergometers that are electronically braked maintain a steady work rate at variable speeds. Several studies have demonstrated a consistent relationship between exercise capacity determined with a treadmill and a cycle ergometer, although the latter mode of exercise tends to produce a lower peak V̇o2.14,15 Cycle ergometry may be preferred in subjects with gait or balance instability, severe obesity, or orthopedic limitations or when simultaneous cardiac imaging is planned. Although arm ergometry may be used to assess the exercise capacity of wheelchair athletes or other individuals with lower-limb disabilities, most persons cannot achieve work rates comparable to those obtained with leg exercise because of the smaller, often deconditioned muscle mass.16The selection of an appropriate exercise test protocol for assessing exercise capacity is important. Exercise test protocols with large stage-to-stage increments in energy requirements generally have a weaker relationship between measured V̇o2 and work rate. The Balke and Ware,17 Naughton,18 and individualized ramp protocols, which involve only modest increases in work rate per stage, are recommended for this reason. Ramp protocols typically involve increments in work rate at intervals of <10 to 60 seconds.19 Regardless of the specific protocol chosen, the protocol should be tailored to the individual to yield a fatigue-limited exercise duration of ≈8 to 12 minutes. Even with exercise test protocols that use modest increases in work rate, results may still indicate a nonlinear relationship between V̇o2 and work rate when test duration is <6 minutes. Conversely, when such protocols result in exercise durations >12 minutes, subjects may terminate exercise because of specific muscle fatigue or orthopedic factors rather than cardiopulmonary end points. In instances in which there is an expectation of >12 minutes of exercise, a test protocol that uses a more progressive approach to increasing work rate, for example, the Bruce protocol,20 should be considered. Finally, minimal or no handrail support should be encouraged when possible during treadmill exercise testing, because handrail support reduces the work performed at any given level and alters the relationship between V̇o2 and work rate.Level of Supervision, Monitoring Issues, and Risk of Adverse EventsMajor complications of exercise testing include death, myocardial infarction, arrhythmia, hemodynamic instability, and orthopedic injury. Fortunately, adverse events are rare during properly supervised tests. Among large series of subjects with and without known disease, serious complications (including myocardial infarction and other events requiring hospitalization) have been reported to occur in <1 to as many as 5 per 10 000 tests, and death has occurred in ≈0.5 per 10 000 tests,21–23 although the incidence of adverse events varies depending on the study population. The safety of CPX was evaluated among 2037 subjects who completed 4411 CPX in the HF-ACTION study (Heart Failure: A Controlled Trial Investigating Outcomes of exercise traiNing). There were no deaths, and the rate of nonfatal major cardiovascular events was <0.5 per 1000 tests.24 Although the event rate is relatively low regardless of the patient population studied, complications resulting from exercise testing do occur. Consequently, it is essential that exercise test supervisory personnel be familiar with the clinical indications for the use of such testing, as well as the signs and symptoms of and clinical responses to adverse events, to minimize patient risk. The American College of Cardiology/American Heart Association clinical competence statement on stress testing outlines a series of cognitive skills necessary for performance, supervision, and interpretation of exercise tests.21 A detailed description of medical supervision and risk stratification for exercise testing is provided elsewhere.6General methodological guidelines for exercise testing laboratories are available.6 Electrocardiographic monitoring of heart rate with multiple-lead electrocardiographic waveforms should be continuous throughout exercise and for at least 6 minutes into recovery for diagnostic testing in patients with suspected disease. It must be recognized that activity-compatible torso electrodes may produce significant changes in electrocardiography morphology compared with standard limb leads. Consequently, the former cannot be used as a substitute for, or for comparison with, the standard resting 12-lead electrocardiogram (ECG).25 Blood pressure should be measured periodically throughout the test, at least at every 2 to 3 minutes and more frequently in some high-risk patients, as well as in recovery during electrocardiographic monitoring. Symptoms, rating of perceived exertion, and dyspnea should be assessed and quantified during and after exercise. When testing patients with implantable cardiac defibrillators, the exercise test personnel should obtain information regarding the programmed implantable cardiac defibrillator settings before beginning the test. The peak heart rate during the test should be kept below the heart rate at which the implantable cardiac defibrillator is programmed to discharge.Reimbursement Coding for CPXTests performed in a CPX laboratory are reimbursable by the Centers for Medicare and Medicaid Services and many private-pay insurance companies. Reimbursement for CPX is billed with Current Procedural Terminology (CPT-4) codes developed by the American Medical Association26 for specific cardiac and pulmonary testing and any adjunct procedures (eg, arterial blood gases) that are performed. All of these tests must be supported with medical necessity using International Classification of Diseases, Ninth Revision27 diagnostic codes. In addition, the Centers for Medicare and Medicaid Services monitors coding using the Correct Coding Initiative28 to ensure that correct coding is used to minimize improper billing and payment from Medicare Part B.CPX tests are coded as either simple or complex. This is determined by the equipment used, variables being measured, and whether additional tests are performed during the procedure. In all cases, specific documentation in the medical record is necessary to provide support for the test and any needed adjunct procedures. Simple pulmonary testing (CPT code 94620) is performed as a telemetry- (3-lead or 12-lead ECG) and pulse oximetry–monitored treadmill, bicycle ergometer, or 6-minute walk test. This test does not require that a physician be present physically, but they must provide general supervision and control of the test. Complex pulmonary testing (CPT code 94621) is performed as a simple pulmonary test with the addition of the metabolic cart to measure V̇o2 and V̇co2. This test requires direct physician presence and supervision during the entire test. Testing for oxygen uptake and expired gas analysis, including CO2 output and O2 percentage, may be obtained and is reimbursable with CPT code 94681. Additional tests such as arterial blood gas measurements have their own CPT codes, which must be included along with the primary test code. These codes include arterial puncture (36600) or arterial catheterization (36620) and blood gas analyzer for blood processing (82803).The CPT code for a cardiac stress test is 93015. If both diagnostic pulmonary and cardiac measurements are performed during the same test, CPT code 93018 is added to either the simple or complex pulmonary testing codes as performed. The Correct Coding Initiative bundles a series of CPT codes together when procedures are typically performed together. For example, spirometry codes (94010, 94060, and 94070) are typically bundled with pulmonary testing codes 94620 and 94621. During a simple pulmonary test, spirometry may be performed at baseline and after exercise, but it is not an essential requirement, so it cannot be bundled with the CPT code 93015.29 Separate interpretive reports of cardiac and pulmonary results must be generated, and each code must be linked to an International Classification of Diseases, Ninth Revision diagnostic code; there must be specific documentation of need for the test in the medical record. Table 3 lists the common Correct Coding Initiative codes for procedures commonly performed in the CPX laboratory. Table 3. Correct Coding Initiative Codes Used in CPX LaboratoriesCCI CodeTest or ProcedureCCI indicates Common Coding Initiative.94620Simple stress pulmonary test94621Complex stress pulmonary test94761Pulse oximetry with multiple determinations93015Cardiac stress test93018Cardiac measurements during a pulmonary test94010Simple spirometry without bronchodilator94060Read and interpret a pulmonary function test94070Spirometry with postexposure bronchospasm94681Oxygen uptake, expired gas analysis (CO2 output, % O2)36600Arterial puncture36620Arterial catheterization82803Blood gas analyzer for blood processingVariables From CPX and Their Physiological ImplicationsStandard MeasuresMaximal Aerobic Capacity: V̇o2max or Peak V̇o2Maximal V̇o2 (V̇o2max) is an important measurement because it is considered to be the metric that defines the limits of the cardiopulmonary system. It is defined by the Fick equation as the product of cardiac output and arteriovenous oxygen difference [C(a−v)O2] at peak exercise: Download figurewhere HR is heart rate and SV is stroke volume. Although Vo2max is measured in liters of oxygen per minute, it is usually expressed in milliliters of oxygen per kilogram of body weight per minute to facilitate intersubject comparisons. This is important,