Capillary porous systems (CPSs) containing liquid lithium are typically fabricated from tungsten fibers. These CPS units are often attached to a steel base using spot welding or simple clamps, methods that are inefficient for transferring high heat flux. In this work, the CPS was integrated into a base structure made of steel (AISI 316LN and AISI 420) and a nickel alloy (Ni34Fe). This study investigated the composite structures under static and cyclic thermal loads, measured their thermal diffusivity, and examined the effects of lithium corrosion. The composite with the Ni34Fe matrix demonstrated the highest resistance to static and cyclic thermal loading and exhibited thermal diffusivity values of up to 8.5 mm2/s. In contrast, composites with steel-based matrices failed after 100 cycles at 500°C/50°C, primarily due to the formation of brittle intermetallic phases. However, the main drawback of the Ni34Fe alloy was its susceptibility to grain boundary corrosion in liquid lithium at 500°C.