微分脉冲伏安法
呋喃唑酮
检出限
电化学
循环伏安法
电极
电化学气体传感器
重复性
材料科学
钛
再现性
线性范围
伏安法
化学
无机化学
分析化学(期刊)
色谱法
物理化学
冶金
抗生素
生物化学
作者
Antolin Jesila Jesu Amalraj,Sea‐Fue Wang
标识
DOI:10.1016/j.jiec.2022.04.018
摘要
Importance in the precise determination of Furazolidone (FZD) on biological, food, and water samples were established for regulating health and nutrition, diagnosis/treatment, pharmacological research, and food/drug quality monitoring. Thus, the sensitive and accurate determination of FZD is necessary. Here, we construct facile and low-cost Metal Titanate (MTiO x , M = Mn, Fe, Cu) as an electrode modifier via a different one-step synthesis method. By the virtue of unique properties, MnTiO 3 has been successfully employed in the electrochemical evaluation of FZD such as high active surface area (0.1252 cm 2 ) and high electron transfer kinetics with low charge transfer resistance (R ct = 374.65 Ω) with good electro-catalytic kinetic parameters. In this regard, MnTiO 3 is employed in the electrochemical evaluation of FZD through cyclic voltammetry (CV) and Differential Pulse Voltammetry (DPV) techniques. The proposed MnTiO 3 /GCE sensor shows exquisite electrochemical characteristics including a wide linear range (0.05 to 1101.6 µM), nanomolar detection limit (4.05 nM), and encouraging sensitivity (68.77 µA µM −1 cm −2 ). Moreover, it also exemplifies exquisite selectivity, repeatability, reproducibility, and storage stability therefore; MnTiO 3 is employed in the practical feasibility analysis in various real samples, which shows excellent recovery results.
科研通智能强力驱动
Strongly Powered by AbleSci AI