Jinlin Zou,Erqi Nie,Fan Liu,Wei Peng,Hua Zhang,Pinjing He
标识
DOI:10.1016/j.envres.2022.114136
摘要
Process monitoring is an essential measure to achieve efficient and stable performance in anaerobic digestion, thus requiring identification of effective early warning indicators. However, the application of early warning indicators to full-scale dry anaerobic engineering biogas plant still remains elusive. This study evaluated the effectiveness of common early warning indicators (including CH4, CO2, H2S, volatile fatty acids (VFAs), alkalinity (ALK), total ammonia concentration (TAN) and free ammonia concentration (FAN)) in monitoring the instability of anaerobic digestion process at a practical engineering plant. The results showed that the individual indicators could not provide a sufficient early warning time before the digester fell into failure collapse. In comparison, the coupling indicators (the ratio of CH4/CO2, CH4/pH, and CH4/H2S) had sensitive response to perturbation, which could regard as a potential early warning indicator, with the early warning time of 6, 7 and 10 days, respectively. Moreover, the VFA/ALK could be used as auxiliary indicators due to the limitation of complex detection methods. In addition, the result also indicated that the application of some warning indicators needs to be further verified, when transferring the result of laboratory scale to the practice application scenarios. This study provides insight into the stable operation of dry anaerobic engineering.