Diagnostic accuracy of ultrasound screening for fetal structural abnormalities during the first and second trimester of pregnancy in low-risk and unselected populations

产科 怀孕 医学 超声波 孕早期 胎儿 孕中期 放射科 生物 遗传学
作者
Marieke F.J. Buijtendijk,B. Bet,Mariska Leeflang,H. Shah,Tom Reuvekamp,Timothy C.D. Goring,Daniël Docter,Melanie GMM Timmerman,Yousif Dawood,Malou A. Lugthart,Bente Berends,Jacqueline Limpens,Eva Pajkrt,Maurice J.B. van den Hoff,Bernadette S. de Bakker
出处
期刊:The Cochrane library [Elsevier]
卷期号:2024 (5) 被引量:8
标识
DOI:10.1002/14651858.cd014715.pub2
摘要

Background Prenatal ultrasound is widely used to screen for structural anomalies before birth. While this is traditionally done in the second trimester, there is an increasing use of first‐trimester ultrasound for early detection of lethal and certain severe structural anomalies. Objectives To evaluate the diagnostic accuracy of ultrasound in detecting fetal structural anomalies before 14 and 24 weeks' gestation in low‐risk and unselected pregnant women and to compare the current two main prenatal screening approaches: a single second‐trimester scan (single‐stage screening) and a first‐ and second‐trimester scan combined (two‐stage screening) in terms of anomaly detection before 24 weeks' gestation. Search methods We searched MEDLINE, EMBASE, Science Citation Index Expanded (Web of Science), Social Sciences Citation Index (Web of Science), Arts & Humanities Citation Index and Emerging Sources Citation Index (Web of Science) from 1 January 1997 to 22 July 2022. We limited our search to studies published after 1997 and excluded animal studies, reviews and case reports. No further restrictions were applied. We also screened reference lists and citing articles of each of the included studies. Selection criteria Studies were eligible if they included low‐risk or unselected pregnant women undergoing a first‐ and/or second‐trimester fetal anomaly scan, conducted at 11 to 14 or 18 to 24 weeks' gestation, respectively. The reference standard was detection of anomalies at birth or postmortem. Data collection and analysis Two review authors independently undertook study selection, quality assessment (QUADAS‐2), data extraction and evaluation of the certainty of evidence (GRADE approach). We used univariate random‐effects logistic regression models for the meta‐analysis of sensitivity and specificity. Main results Eighty‐seven studies covering 7,057,859 fetuses (including 25,202 with structural anomalies) were included. No study was deemed low risk across all QUADAS‐2 domains. Main methodological concerns included risk of bias in the reference standard domain and risk of partial verification. Applicability concerns were common in studies evaluating first‐trimester scans and two‐stage screening in terms of patient selection due to frequent recruitment from single tertiary centres without exclusion of referrals. We reported ultrasound accuracy for fetal structural anomalies overall, by severity, affected organ system and for 46 specific anomalies. Detection rates varied widely across categories, with the highest estimates of sensitivity for thoracic and abdominal wall anomalies and the lowest for gastrointestinal anomalies across all tests. The summary sensitivity of a first‐trimester scan was 37.5% for detection of structural anomalies overall (95% confidence interval (CI) 31.1 to 44.3; low‐certainty evidence) and 91.3% for lethal anomalies (95% CI 83.9 to 95.5; moderate‐certainty evidence), with an overall specificity of 99.9% (95% CI 99.9 to 100; low‐certainty evidence). Two‐stage screening had a combined sensitivity of 83.8% (95% CI 74.7 to 90.1; low‐certainty evidence), while single‐stage screening had a sensitivity of 50.5% (95% CI 38.5 to 62.4; very low‐certainty evidence). The specificity of two‐stage screening was 99.9% (95% CI 99.7 to 100; low‐certainty evidence) and for single‐stage screening, it was 99.8% (95% CI 99.2 to 100; moderate‐certainty evidence). Indirect comparisons suggested superiority of two‐stage screening across all analyses regarding sensitivity, with no significant difference in specificity. However, the certainty of the evidence is very low due to the absence of direct comparisons. Authors' conclusions A first‐trimester scan has the potential to detect lethal and certain severe anomalies with high accuracy before 14 weeks' gestation, despite its limited overall sensitivity. Conversely, two‐stage screening shows high accuracy in detecting most fetal structural anomalies before 24 weeks' gestation with high sensitivity and specificity. In a hypothetical cohort of 100,000 fetuses, the first‐trimester scan is expected to correctly identify 113 out of 124 fetuses with lethal anomalies (91.3%) and 665 out of 1776 fetuses with any anomaly (37.5%). However, 79 false‐positive diagnoses are anticipated among 98,224 fetuses (0.08%). Two‐stage screening is expected to correctly identify 1448 out of 1776 cases of structural anomalies overall (83.8%), with 118 false positives (0.1%). In contrast, single‐stage screening is expected to correctly identify 896 out of 1776 cases before 24 weeks' gestation (50.5%), with 205 false‐positive diagnoses (0.2%). This represents a difference of 592 fewer correct identifications and 88 more false positives compared to two‐stage screening. However, it is crucial to acknowledge the uncertainty surrounding the additional benefits of two‐stage versus single‐stage screening, as there are no studies directly comparing them. Moreover, the evidence supporting the accuracy of first‐trimester ultrasound and two‐stage screening approaches primarily originates from studies conducted in single tertiary care facilities, which restricts the generalisability of the results of this meta‐analysis to the broader population.

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
胡树完成签到,获得积分10
刚刚
刚刚
碧蓝老黑发布了新的文献求助10
1秒前
1秒前
2秒前
2秒前
2秒前
小新新完成签到,获得积分10
2秒前
明亮立诚完成签到,获得积分10
3秒前
Lu_cheung发布了新的文献求助10
4秒前
4秒前
小蘑菇应助范莉采纳,获得10
4秒前
子非鱼完成签到,获得积分10
4秒前
hahaha完成签到,获得积分10
4秒前
小梦游完成签到,获得积分10
4秒前
r12r1完成签到,获得积分10
4秒前
5秒前
5秒前
7秒前
8秒前
Jasper应助狂野的二娘采纳,获得10
8秒前
亮山火马发布了新的文献求助10
8秒前
czq完成签到 ,获得积分10
9秒前
上官若男应助lx采纳,获得10
9秒前
自觉的小蝴蝶完成签到,获得积分10
9秒前
9秒前
hahaha发布了新的文献求助10
10秒前
10秒前
韩东华发布了新的文献求助10
10秒前
11秒前
LJH完成签到,获得积分10
12秒前
范莉完成签到,获得积分10
12秒前
Kk发布了新的文献求助10
14秒前
yyf发布了新的文献求助10
14秒前
15秒前
范莉发布了新的文献求助10
15秒前
16秒前
18秒前
18秒前
18秒前
高分求助中
Adhesion Science: Principles & Practice 1234
Signals, Systems, and Signal Processing 610
The Resilient Mindset 400
Impact of Storage Orientation and Duration on Prefilled Syringe Performance: Break-Loose and Glide Forces, and Injection Time Across Multiple Time Points 360
Programming for Chemical Engineers Using C, C++, and MATLAB 300
Upland Kenya wild flowers and ferns: a flora of the flowers, ferns, grasses, and sedges of highland Kenya 300
Disturbing the Quiet Life? Competition and CEO Incentives 300
热门求助领域 (近24小时)
化学 材料科学 医学 生物 纳米技术 工程类 有机化学 化学工程 生物化学 计算机科学 物理 内科学 复合材料 催化作用 物理化学 光电子学 电极 细胞生物学 基因 无机化学
热门帖子
关注 科研通微信公众号,转发送积分 6652254
求助须知:如何正确求助?哪些是违规求助? 8406220
关于积分的说明 17974624
捐赠科研通 5847575
什么是DOI,文献DOI怎么找? 2971684
邀请新用户注册赠送积分活动 1947133
关于科研通互助平台的介绍 1867589