Comparison of clinical outcomes and capsular bag stability between plate-haptic and C-loop haptic toric IOLs in cataract eyes

医学 眼科 散光 人工晶状体 超声乳化术 视力 眼压 白内障手术 角膜地形图 验光服务 外科 光学 物理
作者
Xin Gao,Dong Zhou,Yi Jiang,Zhinan Liu,Jun Zhang,Guohua Deng
出处
期刊:European Journal of Ophthalmology [SAGE Publishing]
卷期号:35 (6): 1992-2000 被引量:1
标识
DOI:10.1177/11206721251349041
摘要

ObjectiveTo compare the refractive outcomes and rotational stability between a plate-haptic toric intraocular lens (IOL) and a C-loop haptic toric IOL in cataract eyes with corneal astigmatism.MethodsThis was a prospective, randomised, controlled study. 72 patients (72 eyes) with cataracts and corneal astigmatism were randomly divided into 2 groups (Group A: C-loop haptic; Group B: plate-haptic) and underwent phacoemulsification combined with toric IOL implantation at Changzhou Third People's Hospital. The uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BDVA) and residual astigmatism (RAS) were assessed at 1 day, 1 week, 1 month, 3 months postoperatively, while the degree of toric IOL rotation was recorded at 1 week, 1 month, 3 months postoperatively. The correlation between IOL rotation and RAS, intraocular pressure (IOP), axial length (AL), anterior chamber depth (ACD), and white-to-white (WTW) distance was analyzed. Patient satisfaction was evaluated in both groups 3 months postoperatively. Independent sample t-test was used for comparison between the two groups, and repeated measures analysis of variance (ANOVA) was employed to assess changes in IOL rotation, RAS and visual acuity at various postoperative time points. Pearson correlation analysis was used to assess the relationships between continuous variables.ResultsA total of 72 eyes (36 per group) were included with no significant difference in patient characteristics between the two groups. The average postoperative degree of toric IOL rotation in Group A at 1-week, 1-month, and 3-month was greater than that in Group B (8.38 ± 4.19°vs 4.45 ± 2.40°, 7.78 ± 6.87°vs 3.95 ± 2.14°, and 8.23 ± 4.72°vs 4.09 ± 2.12°, respectively, all P < 0.05). Postoperative RAS and spherical equivalent (SE) were better in Group B than Group A (all P < 0.05). More patients in Group B achieved RAS within 0.50D than in Group A (23 vs 14). RAS was positively correlated with IOL rotation in both groups. Patients in Group B achieved a better UDVA than in Group A, whereas no statistical difference in BDVA was found between groups. No significant correlations were found between toric IOL rotation and IOP, AL, ACD, and WTW distance either in Group A or Group B (all P > 0.05). Patient satisfaction was referred as high or very high by 75.0% of patients in Group B compared to 50.0% in Group A. More patients in Group B gained distance spectacle independence than Group A (20 vs 10). No eye-threatening complications were observed intraoperatively or postoperatively. No patients required IOL repositioning during follow-up.ConclusionsThe plate-haptic toric IOL demonstrated superior rotational stability and astigmatism correction than C-loop haptic toric IOL within 3 months postoperatively, which implied that the plate-haptic toric IOL might be a better choice for patients with cataract and corneal astigmatism.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
mxs完成签到,获得积分10
刚刚
刚刚
wjj完成签到,获得积分20
1秒前
maomao发布了新的文献求助10
1秒前
1秒前
布布爱吃炸鸡完成签到,获得积分10
1秒前
1秒前
科研牛马发布了新的文献求助10
2秒前
3秒前
旺旺完成签到,获得积分10
3秒前
3秒前
ii发布了新的文献求助10
4秒前
流露完成签到,获得积分10
4秒前
4秒前
水123发布了新的文献求助10
4秒前
4秒前
执着瓜6发布了新的文献求助20
5秒前
海带完成签到,获得积分10
5秒前
健壮的书桃应助hhh采纳,获得10
5秒前
zain发布了新的文献求助10
5秒前
疏影横斜完成签到 ,获得积分10
6秒前
JG完成签到,获得积分10
6秒前
6秒前
彬彬嘉完成签到,获得积分10
6秒前
yy发布了新的文献求助10
6秒前
7秒前
捕风发布了新的文献求助10
7秒前
7秒前
美味的蟹黄包完成签到 ,获得积分10
7秒前
秦可可完成签到,获得积分20
7秒前
兴奋如松发布了新的文献求助10
8秒前
zc完成签到,获得积分10
8秒前
mBio完成签到,获得积分10
10秒前
Ava应助小车采纳,获得10
10秒前
maomao发布了新的文献求助30
10秒前
晓晓完成签到,获得积分10
10秒前
123456789完成签到,获得积分10
11秒前
科研通AI6.2应助偏偏海采纳,获得10
11秒前
11秒前
12秒前
高分求助中
Principles of Economics, 11th Edition 10000
University Physics with Modern Physics, 16th edition 10000
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
Arthritis and Related Conditions, An Issue of Orthopedic Clinics 1000
Development of a Bridge Weigh-In-Motion System: A technology to convert the bridge response to the passage of traffic into data on vehicle configurations, speeds, times of travel and weights 1000
ズームレンズの光学設計に関する研究 800
Fundamentals of Pharmaceutical and Biologics Regulations: A Global Perspective, Second Edition 700
热门求助领域 (近24小时)
化学 材料科学 医学 生物 纳米技术 工程类 有机化学 化学工程 生物化学 计算机科学 内科学 物理 复合材料 催化作用 细胞生物学 无机化学 光电子学 物理化学 电极 基因
热门帖子
关注 科研通微信公众号,转发送积分 7291451
求助须知:如何正确求助?哪些是违规求助? 8910443
关于积分的说明 18860692
捐赠科研通 6958809
什么是DOI,文献DOI怎么找? 3209327
关于科研通互助平台的介绍 2378998
邀请新用户注册赠送积分活动 2185172