缝隙腐蚀
材料科学
冶金
腐蚀
点蚀
极化(电化学)
电化学
电极
电化学噪声
注射器
奥氏体不锈钢
浓缩池
电化学电池
晶间腐蚀
原电池
作者
José Wilmar Calderón-Hernández,Caruline de Souza Carvalho Machado,Isolda Costa,Hercílio Gomes de Melo
出处
期刊:Corrosion
[NACE International]
日期:2021-09-14
卷期号:77 (12): 1274-1277
被引量:5
摘要
In this study, an electrochemical syringe droplet cell was developed and used to evaluate the pitting corrosion resistance of Type 304 stainless steel. The cell was also adapted to perform measurements in deaerated environment, by means of continuous N2 injection. The results obtained with the syringe cells, in both conditions (aerated and deaerated), were reproducible and free of crevice corrosion because the cell configuration does not allow obtaining this condition. The proposed cell demonstrates coherency with data acquired using conventional cell arrangements, being a potential alternative to study pitting corrosion of passive metals.