Bolong Wei,Shuai Dong,Jun Ma,Yousu Yao
标识
DOI:10.1109/tie.2026.3725397
摘要
Multicoil structures are widely used in wireless power transfer (WPT) systems to extend transfer distance and improve spatial flexibility. However, multiple coils complicate magnetic field analysis, especially leakage field evaluation, which is essential for electromagnetic compatibility. The maximum leakage flux density is commonly used as a leakage indicator. Yet, as the number of coils increases and current amplitudes and phase angles vary, the field becomes highly coupled and nonuniform, making the maximum difficult to determine. Existing methods rely on full-field analysis or limited path/point evaluation, leading to high computational cost or insufficient representativeness. To enable fast evaluation of the leakage magnetic field, this article proposes a virtual co-located coil (VCLC) method. Based on magnetic flux density equivalence, multiple coils are represented by a single VCLC, enabling simplified characterization of the maximum leakage flux density. Compared with full-field scanning, the method restricts spatial traversal to a local region and converts complex magnetic field vector superposition into the field computation of an equivalent single coil, achieving more than 77.14% reduction in computation time. The effectiveness of the method is validated through simulation and experimental results.