生物传感器
粘附
免疫荧光
材料科学
检出限
化学
纳米技术
抗体
色谱法
免疫学
医学
复合材料
作者
Amid Shakeri,Noor Abu Jarad,Jeff Terryberry,Shadman Khan,Ashlyn Leung,Simeng Chen,Tohid F. Didar
出处
期刊:Small
[Wiley]
日期:2020-10-20
卷期号:16 (45): e2003844-e2003844
被引量:50
标识
DOI:10.1002/smll.202003844
摘要
Recent studies have shown a correlation between elevated interleukin 6 (IL-6) concentrations and the risk of respiratory failure in COVID-19 patients. Therefore, detection of IL-6 at low concentrations permits early diagnosis of worst-case outcome in viral respiratory infections. Here, a versatile biointerface is presented that eliminates nonspecific adhesion and thus enables immunofluorescence detection of IL-6 in whole human plasma or whole human blood during coagulation, down to a limit of detection of 0.5 pg mL-1 . The sensitivity of the developed lubricant-infused biosensor for immunofluorescence assays in detecting low molecular weight proteins such as IL-6 is facilitated by i) producing a bioink in which the capture antibody is functionalized by an epoxy-based silane for covalent linkage to the fluorosilanized surface and ii) suppressing nonspecific adhesion by patterning the developed bioink into a lubricant-infused coating. The developed biosensor addresses one of the major challenges for biosensing in complex fluids, namely nonspecific adhesion, therefore paving the way for highly sensitive biosensing in complex fluids.