Qi Chen,Guiwei Li,Zhili Lu,Yuliang Su,Bin Wu,Baoyou Shi
标识
DOI:10.1016/j.jhazmat.2023.131877
摘要
Sufficient and sustainable manganese(II) removal is a challenging task to prevent Mn-related drinking water discoloration problems. This study investigated Mn(II) removal by granular activated carbon (GAC) filtration under various conditions. The results showed that biological GAC filter columns could reduce Mn(II) from 400 μg/L to 10 μg/L after a short ripening period, while sand filter columns did not show evident Mn(II) removal function. Water quality changes, pretreatment with NaClO and chemogenic MnOx coating on GAC media surface did not influence the Mn(II) removal capacity of GAC filter columns. 16S rRNA gene sequencing showed that the abundance of potential Mn(II)-oxidizing bacteria in the GAC media was similar to that in the sand media. However, qPCR results indicated that GAC media colonized dramatically more biomass than sand media, resulting in highly effective Mn(II) removal by GAC filter columns. Under chlorinated conditions, GAC filtration underperformed sand filtration in Mn(II) removal, although activated carbon has been reported to be capable of catalyzing Mn(II) oxidation by chlorine. Fast chlorine decay in GAC filter columns made it hard to sustain chemical Mn(II) oxidation and thus led to less Mn(II) removal. This study highlighted the advantage of biological GAC filtration over sand filtration in Mn(II) removal.