Residual strain and water trees in XLPE and PE cables
作者
Toshikatsu Tanaka,Teruo Fukuda
出处
期刊: [Institute of Electrical and Electronics Engineers] 日期:1974-10-01卷期号:: 239-249被引量:10
标识
DOI:10.1109/ceidp.1974.7735914
摘要
The formation of water trees leads to the deterioration of XLPE and PE cables in service and the shortening of their life. It has been shown that water trees originate from the aggregation of water in high electric field regions by dielectrophoresis.1The growth of water trees is described in this paper.