超声波
薄片
人工智能
冠状面
计算机科学
曲率
计算机视觉
脊柱侧凸
三维超声
医学
放射科
数学
解剖
几何学
外科
作者
Zhichao Liu,Liyue Qian,Wenke Jing,Desen Zhou,Xuming He,Edmond Lou,Rui Zheng
出处
期刊:
[Institute of Electrical and Electronics Engineers]
日期:2021-09-11
卷期号:: 1-4
被引量:10
标识
DOI:10.1109/ius52206.2021.9593343
摘要
Ultrasound spine imaging technique has been applied to the assessment of spine deformity. However, manual measurements of scoliotic angles on ultrasound images are time-consuming and heavily rely on raters' experience. The objectives of this study are to construct a fully automatic framework based on Faster R-CNN for detecting vertebral lamina and to measure the fitting spinal curves from the detected lamina pairs. The framework consisted of two closely linked modules: 1) the lamina detector for identifying and locating each lamina pairs on ultrasound coronal images, and 2) the spinal curvature estimator for calculating the scoliotic angles based on the chain of detected lamina. Two hundred ultrasound images obtained from AIS patients were identified and used for the training and evaluation of the proposed method. The experimental results showed the 76.1% AP on the test set, and the Mean Absolute Difference (MAD) between automatic and manual measurement was 4.3° which was within the clinical acceptance error (5°). Meanwhile the correlation between automatic measurement and Cobb angle from radiographs was 0.79. The results revealed that our proposed technique could provide accurate and reliable automatic curvature measurements on ultrasound spine images for spine deformities.
科研通智能强力驱动
Strongly Powered by AbleSci AI