This paper deals with analysis of the transient and steady-state processes in series (resonant) inverters. Sets of differential and difference equations governing the transient and steady state processes are obtained and solved. The solution is found in closed analytical form. Theoretical and experimental results, both for transient and steady-state conditions, are compared and satisfactory agreement shown.