The experimental researches on PEMFC cold start system were carried out. The response of different factors including the effects of initial temperature, start voltage, and purging time on cold start performance of fuel cell stack were investigated. The experimental results show that the initial temperature of fuel cell stack is lower,and the start-up is harder; in a certain range, the voltage is lower, the cold start performance is better; the cold start performance of fuel cell stack is influenced by the purging period before cold start significantly;the single cell voltage of the stack varies non-uniform during the cold start process.