Technical note: A PET/MR coil with an integrated, orbiting 511 keV transmission source for PET/MR imaging validated in an animal study

衰减校正 成像体模 衰减 核医学 扫描仪 电磁线圈 物理 正电子发射断层摄影术 医学 光学 量子力学
作者
Andreas Renner,Ivo Rausch,Jacobo Cal González,Elmar Laistler,Ewald Moser,Thies H. Jochimsen,Tatjana Sattler,Osama Sabri,Thomas Beyer,Michael Figl,Wolfgang Birkfellner,Bernhard Sattler
出处
期刊:Medical Physics [Wiley]
卷期号:49 (4): 2366-2372 被引量:3
标识
DOI:10.1002/mp.15586
摘要

MR-based methods for attenuation correction (AC) in PET/MRI either neglect attenuation of bone, or use MR-signal derived information about bone, which leads to a bias in quantification of tracer uptake in PET. In a previous study, we presented a PET/MRI specific MR coil with an integrated transmission source (TX) system allowing for direct measurement of attenuation. In phantom measurements, this system successfully reproduced the linear attenuation coefficient of water.The purpose of this study is to validate the TX system in a clinical setting using animals and to show its applicability compared to standard clinical methods.As test subject, a 15-kg piglet was injected with 53 MBq of 18F-NaF. The μ-map obtained with the TX system and the reconstructed activity distribution were compared to four established AC methods: a Dixon sequence, an ultra-short echo time (UTE) sequence, a CT scan, and a 511 keV transmission scan using a Siemens ECAT EXACT HR+ as the reference. The PET/MRI measurements were performed on a Siemens Biograph mMR to obtain the μ-map using the TX system as well as the Dixon and UTE sequence directly followed by the CT and ECAT measurements.The reconstructed activity distribution using the TX system for AC showed similar results compared to the reference (<5% difference in hot regions) and outperformed the MR-based methods as implemented in the PET/MRI system (<10% difference in hot regions). However, the additional hardware of the TX system adds complexity to the acquisition process.Our porcine study demonstrates the feasibility of post-injection transmission scans using the developed TX system in a clinical setting. This makes it a useful tool for PET/MRI in cases where transmission information is needed for AC. Potential applications are studies using larger animals where state-of-the-art atlas-based or artificial intelligence AC methods are not available.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
大幅提高文件上传限制,最高150M (2024-4-1)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
万能图书馆应助Brightan采纳,获得10
1秒前
2秒前
医生发布了新的文献求助10
3秒前
轻松雨旋完成签到 ,获得积分10
3秒前
温暖果汁发布了新的文献求助10
5秒前
blue2021发布了新的文献求助10
6秒前
shinysparrow应助于伯云采纳,获得10
6秒前
shinysparrow应助RK采纳,获得10
7秒前
8秒前
Ava应助谢佳冀采纳,获得10
8秒前
10秒前
wankai发布了新的文献求助10
15秒前
zhul09完成签到,获得积分10
15秒前
boom完成签到 ,获得积分10
16秒前
Bminor完成签到,获得积分10
16秒前
花样年华发布了新的文献求助30
18秒前
23秒前
贪玩小小完成签到 ,获得积分10
23秒前
Sammy完成签到,获得积分10
24秒前
27秒前
小蘑菇应助blue2021采纳,获得10
27秒前
完美世界应助未来无限采纳,获得10
29秒前
害羞迎南发布了新的文献求助250
32秒前
33秒前
cctv18应助壮观以松采纳,获得10
33秒前
自私的猫发布了新的文献求助10
34秒前
39秒前
Hello应助温暖果汁采纳,获得10
42秒前
123~!完成签到,获得积分10
43秒前
blue2021发布了新的文献求助10
44秒前
51秒前
orixero应助鹿晓亦采纳,获得10
52秒前
54秒前
未来无限完成签到,获得积分10
55秒前
55秒前
wj完成签到 ,获得积分10
56秒前
Dicy发布了新的文献求助10
58秒前
1分钟前
1分钟前
诚心的三毒完成签到,获得积分20
1分钟前
高分求助中
Manual of Clinical Microbiology, 4 Volume Set (ASM Books) 13th Edition 1000
Teaching Social and Emotional Learning in Physical Education 900
Boris Pesce - Gli impiegati della Fiat dal 1955 al 1999 un percorso nella memoria 500
Chinese-English Translation Lexicon Version 3.0 500
Recherches Ethnographiques sue les Yao dans la Chine du Sud 500
Two-sample Mendelian randomization analysis reveals causal relationships between blood lipids and venous thromboembolism 500
[Lambert-Eaton syndrome without calcium channel autoantibodies] 460
热门求助领域 (近24小时)
化学 材料科学 医学 生物 有机化学 工程类 生物化学 纳米技术 物理 内科学 计算机科学 化学工程 复合材料 遗传学 基因 物理化学 催化作用 电极 光电子学 量子力学
热门帖子
关注 科研通微信公众号,转发送积分 2397569
求助须知:如何正确求助?哪些是违规求助? 2099082
关于积分的说明 5291285
捐赠科研通 1826983
什么是DOI,文献DOI怎么找? 910658
版权声明 560023
科研通“疑难数据库(出版商)”最低求助积分说明 486763