桁架
结构工程
安全系数
欧洲规范
屈曲
工程类
结构体系
屋顶
非线性系统
负荷系数
有限元法
极限状态设计
量子力学
物理
作者
Lauri Jaamala,Kristo Mela,Juha Tulonen,Anssi Hyvärinen
标识
DOI:10.1016/j.engstruct.2023.116198
摘要
Eurocode allows for the design of structural systems by advanced analysis, i.e. by Geometrically and Materially Nonlinear Imperfection Analysis (GMNIA). In GMNIA, the entire structural system is designed by carrying out a nonlinear finite element analysis and by comparing the load proportionality factor obtained from the analysis to the predetermined system safety factor. This study determines the required Eurocode-compliant GMNIA system safety factor for the ultimate limit state design of Warren-type roof trusses. The system safety factor is determined based on system-level reliability studies conducted for 15 trusses. The investigated trusses are made of cold-formed rectangular hollow sections having a nominal yield strength of 700 MPa. The determined system safety factor is then applied for comparison calculations, in which three trusses are designed both by GMNIA and the conventional EN 1993-1-1 method. This comparison reveals a need for an accurate modelling method of hollow section connections in GMNIA. Furthermore, the comparison shows that GMNIA can offer reduced material consumption compared to the conventional method even in roof trusses, in which load redistribution capabilities are very limited. This reduction is achieved due to capability of GMNIA to accurately capture the buckling capacities of continuous top chords, whereas the conventional method must rely on conservative approximations of buckling lengths.