化学
胸腺嘧啶
水溶液中的金属离子
费斯特共振能量转移
荧光
荧光团
水溶液
检出限
部分
离子
光化学
分析化学(期刊)
DNA
立体化学
物理化学
色谱法
有机化学
物理
量子力学
生物化学
作者
Huiwang Wu,Xueping Liu,Jian‐Hui Jiang,Guo‐Li Shen,Ru‐Qin Yu
标识
DOI:10.1002/cjoc.200990260
摘要
A highly selective fluorescence sensor was developed for Hg(II) ion detection in aqueous solutions based on the selective binding of Hg(II) ions with a pair of thymine‐thymine mismatch. The sensor consists of two DNA probes functionalized with a fluorophore (fluorescein, F) and a quencher (tetramethyl rhodamine, Q) moiety separately. This pair of DNA probes contains two pairs of thymine‐thymine mismatches used to detect Hg(II) ions. In the presence of Hg(II) ions, thymine‐Hg2+‐thymine was formed between thymine residues of probes. From that, the interaction of the two DNA probes increased. Thus, the DNA probes formed a double‐stranded structure. Both the fluorophore and quencher were brought close to each other leading to the fluorescence resonance energy transfer (FRET) between F and Q. Under the optimum conditions, the sensor was used to detect the Hg(II) ions from 50 to 1000 nmol·L−1 with a regression equation y=5281.13−1650.56 lg[Hg2+] (R2=0.985). The linear range covers 100 to 500 nmol·L−1, and the limit of detection (LOD) is 79 nmol·L−1. The disturbance of some co‐existing metal ions was explored, and no significant fluorescence quenching in the presence of 1.0 μmol·L−1 other metal ions was observed. The fluorescence sensor has good sensitivity and selectivity for Hg(II) ions providing a rapid, simple and low cost method for the detection of mercury(II) ions in aqueous solutions.
科研通智能强力驱动
Strongly Powered by AbleSci AI