Comparison of a flexible versus rigid bone cement injection system in unilateral percutaneous vertebroplasty

经皮椎体成形术 医学 骨水泥 水泥 经皮 外科 柯布角 椎体压缩性骨折 显著性差异 腰椎 放射科 椎体 牙科 射线照相术 材料科学 冶金 内科学
作者
Yuwei Li,Wei Cui,Peng Zhou,Cheng Li,Yan Wen,Wei Xiao
出处
期刊:European Journal of Medical Research [BioMed Central]
卷期号:25 (1) 被引量:5
标识
DOI:10.1186/s40001-020-00436-z
摘要

Abstract Background Percutaneous vertebroplasty (PVP) has been demonstrated to be effective in the treatment of acute osteoporotic vertebral fracture (AOVF). However, bilateral puncture takes more time to accept more X-ray irradiation; some scholars apply unilateral puncture PVP, but the cement cannot be symmetrically distributed in the vertebral body, so we use a flexible cement injector that undergoes PVP through the unilateral pedicle puncture. This research aims to compare the clinical results of PVP for AOVF with unilateral pedicle puncture using a straight bone cement injector and a bendable cement injector, determine the value of a bendable cement injector. Methods We undertook a retrospective analysis of patients with thoracic and lumbar compression fracture treated with unilateral pedicle puncture percutaneous vertebroplasty from our institution from June 2013 to July 2015. Operation time, radiation exposure, bone cement injection amount, and the incidence of bone cement leakage were recorded on presentation, the cement leakage was measured by X-ray and computed tomography scan. The patients were followed up postoperatively and were assessed mainly with regard to clinical and radiological outcomes. Results There was no significant difference in the operation time, radiation exposure time and incidence of bone cement leakage between the two groups. There was significant difference in the amount of bone cement injection and the difference between the two groups. There were no significant differences in VAS and the relative height of the vertebral body and local Cobb angle and QUALEFFO between the two groups at 1 week after PVP, significant difference was observed only 12 months after operation. Conclusions Application of flexible cement injector is safe and feasible, compared with the application of straight bone cement injector, without prolonging the operative time, radiation exposure time and the incidence of bone cement leakage; it has the advantages of good long-term effect and low incidence of vertebral fracture recurrence.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
kkk完成签到,获得积分10
1秒前
小飞飞应助斑比采纳,获得20
1秒前
1秒前
Besty完成签到 ,获得积分10
4秒前
5秒前
jenningseastera应助shencheng采纳,获得10
5秒前
5秒前
nzh19802完成签到,获得积分10
6秒前
博闻发布了新的文献求助10
7秒前
10秒前
Gauss应助科研通管家采纳,获得30
11秒前
充电宝应助科研通管家采纳,获得10
11秒前
顾矜应助科研通管家采纳,获得10
11秒前
11秒前
共享精神应助科研通管家采纳,获得10
11秒前
大个应助科研通管家采纳,获得10
11秒前
CodeCraft应助科研通管家采纳,获得10
11秒前
华仔应助科研通管家采纳,获得10
11秒前
11秒前
11秒前
nzh19802发布了新的文献求助10
11秒前
11秒前
11秒前
马保国123完成签到,获得积分10
12秒前
ZSQ完成签到,获得积分10
13秒前
SZ发布了新的文献求助20
15秒前
17秒前
17秒前
Capybara完成签到,获得积分10
19秒前
博闻完成签到,获得积分10
19秒前
19秒前
20秒前
20秒前
清欢完成签到,获得积分10
20秒前
学术垃圾1984完成签到,获得积分10
22秒前
三三完成签到,获得积分10
24秒前
潇洒皮带完成签到,获得积分10
24秒前
28秒前
Jasper应助奋斗的菲鹰采纳,获得10
28秒前
NexusExplorer应助木木杨采纳,获得50
28秒前
高分求助中
【此为提示信息,请勿应助】请按要求发布求助,避免被关 20000
Technologies supporting mass customization of apparel: A pilot project 450
Mixing the elements of mass customisation 360
Периодизация спортивной тренировки. Общая теория и её практическое применение 310
the MD Anderson Surgical Oncology Manual, Seventh Edition 300
Nucleophilic substitution in azasydnone-modified dinitroanisoles 300
Political Ideologies Their Origins and Impact 13th Edition 260
热门求助领域 (近24小时)
化学 材料科学 医学 生物 工程类 有机化学 物理 生物化学 纳米技术 计算机科学 化学工程 内科学 复合材料 物理化学 电极 遗传学 量子力学 基因 冶金 催化作用
热门帖子
关注 科研通微信公众号,转发送积分 3781475
求助须知:如何正确求助?哪些是违规求助? 3327071
关于积分的说明 10229393
捐赠科研通 3041969
什么是DOI,文献DOI怎么找? 1669742
邀请新用户注册赠送积分活动 799258
科研通“疑难数据库(出版商)”最低求助积分说明 758757