色谱法
维生素D与神经学
化学
钙二醇
代谢物
维生素
再现性
离心
维生素D缺乏
医学
内科学
生物化学
作者
Neus Fabregat-Cabello,Jordi Farré-Segura,Loreen Huyghebaert,Stéphanie Peeters,Caroline Le Goff,Paule Latino‐Martel,Étienne Cavalier
标识
DOI:10.1016/j.cca.2017.08.024
摘要
Rapid, easy and reliable measurement of the major vitamin D metabolites is required in order to fulfill the needs of a clinical routine laboratory. To overcome these challenges, we have developed and validated a LC-MS/MS method for the quantification of 25-hydroxyvitamin D2 and D3, epi-25-hydroxyvitamin D3 and 24,25-dihydroxyvitamin D3.Sample preparation was based on precipitation and centrifugation of 100μL of patient serum, followed by injection into the LC-MS/MS system. Samples from Vitamin D Standardization Program (n=80) and patient samples (n=281) have been compared with a reference LC-MS/MS method. For the analytical validation NIST and Labquality quality control materials were used.Mean intra-assay and inter-assay imprecision were <6.0 and 6.4% and mean recoveries were within 95-104%. LOQ's were 0.5μg/L for 24,25(OH)2D3, 1.1μg/L for 25(OH)D3 and epi-25(OH)D3 and 1.7μg/L for 25(OH)D2. A 3% bias obtained between the proposed and the reference method satisfies Vitamin D Standardization Program recommendations.We present a rapid, easy, reliable and cost-effective method completely adequate for routine testing, which permits the measurement of the ratio of 24,25-dihydroxyvitamin D to 25-hydroxyvitamin D, Vitamin D Metabolite Ratio (VMR), in serum samples.