Accuracy of freehand versus guided immediate implant placement: A randomized controlled trial

随机对照试验 医学 植入 牙科 口腔正畸科 外科
作者
Segin Chandran K R,Manoj Goyal,Neeti Mittal,Jensy Sara George
出处
期刊:Journal of Dentistry [Elsevier BV]
卷期号:136: 104620-104620 被引量:26
标识
DOI:10.1016/j.jdent.2023.104620
摘要

This randomized controlled trial (RCT) aimed to compare the accuracy of immediate implant placement with freehand and static guided surgery.An RCT was conducted on 61 subjects who received a total of 80 dental implants. The enrolled patients were randomly allocated to two groups: freehand surgery (control group, n = 40 implants) and static guided surgery with R2Gate® (Megagen, Gyeongbuk, South Korea, test group, n = 40 implants). Crestal and apical deviations in both mesiodistal and buccolingual dimensions, as well as depth and angular deviations, were calculated by comparing the three-dimensional (3D) position of the implant in the planning software with the final implant position, revealed by an intraoral scan of the fixture after placement. The Mann-Whitney test was used for comparative assessment.In the freehand group (control), crestal deviations of 1.13 ± 0.89 mm and 1.00 ± 0.76 mm were found in the mesiodistal and buccolingual directions, respectively, versus 0.34 ± 0.26 mm (p<0.001) and 0.37 ± 0.24 mm (p = 0.03) in the static guided surgery group (test). Apical deviation was also higher in the freehand group (control) than in the static guided surgery group (test) in the mesiodistal (4.04 ± 1.90 mm vs. 0.97 ± 0.55 mm, p = 0.04) and buccolingual directions (3.46 ± 1.82 mm vs. 0.94 ± 0.67 mm, p = 0.02). Freehand surgery had greater angular deviation (6.09° ± 3.23) compared to guided surgery (0.83° ± 0.53, p = 0.02). However, depth deviation was similar in the freehand surgery group (2.24 ± 1.58 mm) and static guided surgery group (0.66 ± 0.43, p = 0.09).Immediate implant placement with static guided surgery demonstrated better accuracy than freehand surgery.Guided implant surgery showed fewer deviations compared to freehand surgery in fresh extraction sockets; therefore, the use of static guides should be given preference over the freehand modality.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
PDF的下载单位、IP信息已删除 (2025-6-4)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
zhz完成签到,获得积分10
2秒前
YH应助科研通管家采纳,获得100
2秒前
英姑应助科研通管家采纳,获得10
2秒前
Lucas应助科研通管家采纳,获得10
2秒前
2秒前
2秒前
科研通AI2S应助科研通管家采纳,获得10
2秒前
2秒前
zwy完成签到 ,获得积分10
9秒前
爆米花应助嗯哼哈哈采纳,获得10
12秒前
十月天秤完成签到,获得积分0
13秒前
风清扬应助123采纳,获得10
13秒前
中海完成签到,获得积分10
13秒前
勇往直前完成签到,获得积分10
18秒前
yar应助中海采纳,获得10
18秒前
等待的幼晴完成签到,获得积分10
19秒前
20秒前
GOD伟完成签到,获得积分10
20秒前
俭朴从安完成签到,获得积分10
21秒前
Jasmineyfz完成签到 ,获得积分10
21秒前
小马甲应助Ygy采纳,获得10
24秒前
25秒前
酪酪Alona发布了新的文献求助10
26秒前
嗯哼哈哈发布了新的文献求助10
29秒前
saf0852完成签到,获得积分10
31秒前
zrrr完成签到 ,获得积分10
37秒前
最爱吃芒果完成签到,获得积分10
37秒前
沉沉完成签到 ,获得积分0
42秒前
子卿完成签到,获得积分0
44秒前
SC武完成签到,获得积分10
45秒前
Tree完成签到 ,获得积分10
47秒前
开朗万天完成签到 ,获得积分10
48秒前
顾瞻完成签到,获得积分10
50秒前
SYLH应助快乐的鱼采纳,获得10
50秒前
晨雾锁阳完成签到 ,获得积分10
50秒前
zhang完成签到 ,获得积分10
52秒前
素律完成签到,获得积分10
57秒前
123完成签到,获得积分10
57秒前
李思超完成签到 ,获得积分10
58秒前
风信子完成签到,获得积分10
1分钟前
高分求助中
ФОРМИРОВАНИЕ АО "МЕЖДУНАРОДНАЯ КНИГА" КАК ВАЖНЕЙШЕЙ СИСТЕМЫ ОТЕЧЕСТВЕННОГО КНИГОРАСПРОСТРАНЕНИЯ 3000
Electron microscopy study of magnesium hydride (MgH2) for Hydrogen Storage 1000
生物降解型栓塞微球市场(按产品类型、应用和最终用户)- 2030 年全球预测 500
Nucleophilic substitution in azasydnone-modified dinitroanisoles 500
Quantum Computing for Quantum Chemistry 500
Thermal Expansion of Solids (CINDAS Data Series on Material Properties, v. I-4) 470
Canon of Insolation and the Ice-age Problem 400
热门求助领域 (近24小时)
化学 材料科学 医学 生物 工程类 有机化学 物理 生物化学 纳米技术 计算机科学 化学工程 内科学 复合材料 物理化学 电极 遗传学 量子力学 基因 冶金 催化作用
热门帖子
关注 科研通微信公众号,转发送积分 3900207
求助须知:如何正确求助?哪些是违规求助? 3444935
关于积分的说明 10837181
捐赠科研通 3170070
什么是DOI,文献DOI怎么找? 1751447
邀请新用户注册赠送积分活动 846706
科研通“疑难数据库(出版商)”最低求助积分说明 789363