OBJECTIVES: We aimed to evaluate the effect of intratumoral perfusion on microwave ablation (MWA) area in hepatocellular carcinoma (HCC). METHODS: Patients who underwent curative MWA for HCC between October 2013 and May 2015 were enrolled. Three days before MWA, contrast-enhanced ultrasound (CEUS) was performed to illustrate the perfusion characteristics of the target lesion. Using the Sonoliver quantification software, time-intensity curves of dynamic CEUS were obtained, and quantitative parameters were extracted. Two microwave antennae were inserted into the center of the tumor and MWA was performed with a continuous power output of 50 W for 5 min. A second CEUS was performed to measure the size of the ablated region. Thereafter, an additional MWA procedure was performed until complete ablation with a 5-10-mm safety margin was achieved. RESULTS: A total of 38 patients who underwent curative MWA for 39 HCC nodules were enrolled. The mean age was 57 years (34-80 years), and the median maximum diameter of the HCC was 3.4 cm (interquartile range, 2-6.8 cm). Time-intensity curves were obtained and the area under the curve (AUC) was selected as a parameter for intratumoral perfusion. The AUC was inversely and linearly correlated with the size of the MWA area, including long- and short-axis diameters and ablation volume. A 1,000-dB·s change in the AUC produced an average change of 1.17 ± 0.44 mm, 0.725 ± 0.355 mm, and 2.4995 ± 0.6575 cm³ in the long- and short-axis diameters and ablation volume, respectively. CONCLUSIONS: The intratumoral perfusion of HCC was inversely correlated with MWA area size.