Bacterial biofilm formation on implant surfaces is a major problem because it contributes to peri-implant mucosal inflammation and subsequent peri-implant bone loss. Therefore, it is of interest to compare the early multispecies oral biofilm formation on polished titanium, sandblasted and acid-etched titanium, polished zirconia and roughened zirconia discs. A total of 120 sterile discs were exposed to salivary-pellicle mixed bacterial suspension and incubated for 24, 48 and 72 hours, followed by assessment of optical density, colony-forming units, confocal biofilm thickness and scanning electron microscopic surface coverage. At 72 hours, rough titanium showed the highest biofilm biomass, viable count and surface coverage, whereas polished zirconia showed the lowest values, with statistically significant differences among groups (p<0.001). Thus, polished zirconia showed reduced biofilm formation compared with titanium, suggesting its potential usefulness as a biologically favorable implant-abutment material in patients at risk of plaque accumulation.