作者
Fabiano Mattesco,Victor Dorsa,Mariana Viana,Sérgio Tufik,Nathalia Oliveira
摘要
Abstract Background Vitamin C (ascorbic acid) is an essential micronutrient widely recognized for its crucial role in physiological processes, including antioxidant defense, collagen synthesis, immune system maintenance, and the facilitation of multiple enzymatic reactions. Plasma vitamin C analysis is frequently performed by high-performance liquid chromatography (HPLC), which is considered one of the most robust and reliable methodologies for quantifying compounds in complex matrices. In view of the increasing demand for rapid, cost-effective, and sustainable analyses, optimization strategies have been sought to enhance analytical efficiency without compromising quality and analytical performance, such as the use of smaller chromatographic columns. The aim of this study was to evaluate analytical performance and method transferability between two chromatographic columns with different dimensions for plasma vitamin C determination by HPLC. Methods Twenty plasma samples were prepared and injected into an Agilent 1260 Infinity II HPLC system and included for comparative analytical evaluation. The chromatographic system was equipped with a UV detector set at 245nm for vitamin C detection, using a mobile phase composed of 0.5% formic acid in ultrapure water. Samples were injected into two C18 chromatographic columns to allow direct performance comparison. The columns differed in length, internal diameter, and particle size: a larger-dimension column, Reprospher 100 C18-Aqua 125 × 4 mm, 5 µm (Dr. Maisch®) (column A), and a smaller-dimension column, Kinetex 2.6 µm EVO C18 100 Å 50 × 2.1 mm (Phenomenex®) (column B). Analytical performance was assessed by evaluating retention time, mobile phase consumption, and comparison of the determined vitamin C concentrations. The coefficient of determination (R²) was calculated to assess the correlation between methods, adopting an acceptance criterion of R² >= 0.950 and a Total Allowable Error (TAE) of 15%, previously established by the laboratory in accordance with CLSI guidelines. Results Column B, with shorter length and smaller internal diameter, showed a retention time of approximately 0.581 minutes for vitamin C, whereas column A exhibited a retention time of about 1.947 minutes, representing a 70.1% reduction. Column B also resulted in an approximate 75% decrease in mobile phase consumption per injection compared to column A. The vitamin C concentrations determined in plasma samples were consistent between analyses performed with both columns, with no significant differences observed. All results were within the established TAE, and the coefficient of determination was 0.992, confirming the absence of statistical bias between the tested columns. Method agreement between columns demonstrated analytical equivalence despite substantial reductions in analysis time and solvent consumption. Conclusion The results demonstrate that the use of a smaller-dimension chromatographic column is an effective strategy to accelerate plasma vitamin C analysis by HPLC, achieving shorter retention times and substantial savings in mobile phase consumption without compromise analyte quantification accuracy or reproducibility, supporting a more efficient analytical workflow. Chromatographic columns with reduced length and internal diameter therefore represent a robust and advantageous alternative for plasma vitamin C determination by HPLC, particularly for high-throughput applications requiring rapid analysis and cost reduction without compromising analytical reliability.