热电偶
温度测量
材料科学
温度梯度
结温
光电子学
电气工程
复合材料
热的
工程类
物理
热力学
量子力学
作者
M. He,Bian Tian,Zhongkai Zhang,X. G. Fan,Zhaojun Liu,Luntao Chen,Xudong Fang
标识
DOI:10.1109/tim.2025.3551568
摘要
The thin-film thermocouples (TFTCs) are widely utilized in high-temperature measurements due to their superior capabilities. However, under extreme high-temperature conditions and complex heat transfer scenarios, the cold junction temperature can rise uncontrollably, reducing the temperature gradient between junctions, presenting challenges in achieving high-precision measurements. This study introduces a novel dual-junction TFTC design, combining three selected sensitive materials using a multilayer perceptron (MLP) approach, fabricated through a screen-printing method. The calibration of the dual-junction TFTC was accomplished using an integrated learning model, achieving a measurement range of$900~^{\circ }$C. For cold junction temperatures from$0~^{\circ }$C to$500~^{\circ }$C, we predicted the hot junction temperature based on electromotive force alone. Compared to a K-type thermocouple, the average relative error in the predicted hot junction temperature across 29 experimental samples with small gradients was 1.07%. Additionally, we predicted the real-time cold junction temperature, with an average relative error of 2.91%. This work achieves accurate measurement of both junction temperatures under unstable cold junction conditions, enhancing the measurement precision of TFTCs and eliminating the need for compensation wires and water-cooling devices.
科研通智能强力驱动
Strongly Powered by AbleSci AI