已入深夜,您辛苦了!由于当前在线用户较少,发布求助请尽量完整地填写文献信息,科研通机器人24小时在线,伴您度过漫漫科研夜!祝你早点完成任务,早点休息,好梦!

Measurement of Frontal Midline Theta Oscillations using OPM-MEG

脑磁图 仪表(计算机编程) 计算机科学 噪音(视频) 人工智能 物理 声学 脑电图 神经科学 心理学 操作系统 图像(数学)
作者
Natalie Rhodes,Molly Rea,Elena Boto,Lukas Rier,Vishal Shah,Ryan M. Hill,James Osborne,Cody Doyle,Niall Holmes,Sebastian Coleman,Karen J. Mullinger,Richard Bowtell,Matthew J. Brookes
出处
期刊:NeuroImage [Elsevier BV]
卷期号:271: 120024-120024 被引量:56
标识
DOI:10.1016/j.neuroimage.2023.120024
摘要

Optically pumped magnetometers (OPMs) are an emerging lightweight and compact sensor that can measure magnetic fields generated by the human brain. OPMs enable construction of wearable magnetoencephalography (MEG) systems, which offer advantages over conventional instrumentation. However, when trying to measure signals at low frequency, higher levels of inherent sensor noise, magnetic interference and movement artefact introduce a significant challenge. Accurate characterisation of low frequency brain signals is important for neuroscientific, clinical, and paediatric MEG applications and consequently, demonstrating the viability of OPMs in this area is critical. Here, we undertake measurement of theta band (4-8 Hz) neural oscillations and contrast a newly developed 174 channel triaxial wearable OPM-MEG system with conventional (cryogenic-MEG) instrumentation. Our results show that visual steady state responses at 4 Hz, 6 Hz and 8 Hz can be recorded using OPM-MEG with a signal-to-noise ratio (SNR) that is not significantly different to conventional MEG. Moreover, we measure frontal midline theta oscillations during a 2-back working memory task, again demonstrating comparable SNR for both systems. We show that individual differences in both the amplitude and spatial signature of induced frontal-midline theta responses are maintained across systems. Finally, we show that our OPM-MEG results could not have been achieved without a triaxial sensor array, or the use of postprocessing techniques. Our results demonstrate the viability of OPMs for characterising theta oscillations and add weight to the argument that OPMs can replace cryogenic sensors as the fundamental building block of MEG systems.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
2秒前
2秒前
文慧完成签到,获得积分10
2秒前
2秒前
簌落发布了新的文献求助10
2秒前
3秒前
搜集达人应助小怪兽采纳,获得10
3秒前
九个烧卖完成签到,获得积分10
4秒前
李李发布了新的文献求助10
4秒前
闫闫完成签到 ,获得积分10
4秒前
ding应助ZG采纳,获得10
4秒前
5秒前
5秒前
故意的笑南完成签到 ,获得积分10
5秒前
8秒前
linzhihang发布了新的文献求助10
8秒前
张行完成签到,获得积分10
9秒前
9秒前
传奇3应助科研通管家采纳,获得10
9秒前
汉堡包应助科研通管家采纳,获得10
10秒前
10秒前
上官若男应助科研通管家采纳,获得10
10秒前
梁33完成签到,获得积分10
11秒前
11秒前
13秒前
xiaomeng完成签到 ,获得积分10
13秒前
李健应助Dong采纳,获得10
14秒前
思源应助linzhihang采纳,获得10
14秒前
14秒前
smg1307发布了新的文献求助10
15秒前
要自由发布了新的文献求助10
15秒前
18秒前
19秒前
龙傲天发布了新的文献求助10
19秒前
李爱国应助默默的如凡采纳,获得10
19秒前
21秒前
22秒前
3321完成签到 ,获得积分10
22秒前
Ellalala完成签到 ,获得积分10
23秒前
科研通AI6.2应助yjj6809采纳,获得10
25秒前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
Applied Min-Max Approach to Missile Guidance and Control 5000
Metallurgy at high pressures and high temperatures 2000
Inorganic Chemistry Eighth Edition 1200
The Psychological Quest for Meaning 800
Signals, Systems, and Signal Processing 610
An Introduction to Medicinal Chemistry 第六版习题答案 600
热门求助领域 (近24小时)
化学 材料科学 医学 生物 纳米技术 工程类 有机化学 化学工程 生物化学 计算机科学 物理 内科学 复合材料 催化作用 物理化学 光电子学 电极 细胞生物学 基因 无机化学
热门帖子
关注 科研通微信公众号,转发送积分 6329325
求助须知:如何正确求助?哪些是违规求助? 8145742
关于积分的说明 17086666
捐赠科研通 5383844
什么是DOI,文献DOI怎么找? 2855276
邀请新用户注册赠送积分活动 1832887
关于科研通互助平台的介绍 1684151