多物理
振动
声学
非线性系统
模态分析
超声波传感器
材料科学
计算机科学
偏转(物理)
情态动词
振幅
还原(数学)
有限元法
噪音(视频)
谐波平衡
建模与仿真
降噪
联轴节(管道)
航空航天
控制理论(社会学)
绕固定轴旋转
隔振
机械
干扰(通信)
计算机模拟
激光多普勒测振仪
滤波器(信号处理)
旋转(数学)
脉冲(物理)
扭转振动
超声波检测
频率响应
激发
结构工程
机械系统
机械工程
作者
C.Y. Wang,Liujuan Zhu,Hongbo Fu,Huaishu Hou
标识
DOI:10.1088/1361-6501/ae1e23
摘要
Abstract The widespread application of complex curved surface components in aerospace and precision instruments has raised higher requirements for their non-destructive testing accuracy. Rotational ultrasonic inspection devices need to maintain stability under high-frequency vibration and multi-axis motion coupling conditions. To address issues such as significant vibration interference and poor motion stability in complex curved surface rotational ultrasonic inspection devices, this study proposes a research method based on multi-body dynamics modeling and multiphysics coupled simulation. Innovatively, a multi-body dynamic model including the rotation axis system and probe holder is established, linking structural characteristics with contact mechanics models. The ADAMS-MATLAB multiphysics collaborative simulation is employed to quantify the relationship between vibration characteristics and motion accuracy. A multi-dimensional vibration and mechanical parameter acquisition network is constructed, and a direct-form parallel finite impulse response (FIR) structure is designed to balance real-time performance and noise reduction precision. The results show that the maximum vibration amplitude of key components (marker2/marker3) in the X direction is 0.73 mm, and in the Y direction is 0.5 mm, exhibiting symmetrical deflection vibration characteristics around the Y -axis and X -axis. In summary, the multiphysics coupled simulation method can effectively reveal the nonlinear vibration patterns of the device. Additionally, the direct parallel FIR filter proposed in this study, designed through a multi-tap delay chain and a 100 Hz low-pass coefficient, effectively suppresses high-frequency interference introduced by ultrasonic excitation at 20–40 kHz. After filtering, the X -direction vibration amplitude at point marker12 decreases from 0.3 mm to 0.15 mm, a reduction of 50%. This study provides methodological support for the dynamic performance optimization of complex curved surface ultrasonic inspection equipment. Its significance lies in improving vibration stability and motion accuracy via multiphysics coupling simulation. A rod system with water immersion forms a damping layer, suppressing vibration, solving stability issues, and supporting non-destructive testing.
科研通智能强力驱动
Strongly Powered by AbleSci AI