SENSE and Compressed SENSE chemical shift encoded multi-gradient echo for T2* quantification in the liver
作者
Elisabeth Pickles,John J. Connell,Stella Kin,Alison Telford,Arina Kazimianec,Michael Brady,Daniel Peter Bulte,Oi Fong Chong,Han Jun Choo,Sulaiha Binte Ithnin,Jason Pik-Eu Chang,Guan Huei Lee,Marianne Anastasia De Roza,Kok Kiong Ong,Sabrina Yi-Mei Wee,Kee Tung Tan,Ngiap Chuan Tan,Han Chong Toh,Yu Jun Wong,Wei Lyn Yang
出处
期刊:日期:2023-08-03
标识
DOI:10.58530/2022/1937
摘要
T2*, measured using 3D breath-hold chemical shift encoded multi-gradient echo can be used to estimate liver iron concentration. The breath-hold duration (typically 10-20 s) with traditional parallel imaging acceleration techniques such as Sensitivity Encoding (SENSE) can be difficult for patients. Compressed SENSE (C-SENSE) can be used to decrease acquisition time. We compare T2* obtained with SENSE and C-SENSE in 21 patients. We found that C-SENSE acquisition was faster (9 s vs 18 s), with strong correlation and agreement with SENSE. Our findings suggest C-SENSE may potentially improve patient tolerance and turnover speed for T2* acquisitions when compared to SENSE.